USER’S GUIDE

Failure during read of file <file name> for WAN card in slot <slot # >

If seen repeatedly, the above message indicates a problem with your hard drive. Contact your Distributor or Customer Support.

Failure during read of file ’s’

The WAN card initialization subsystem encountered an error reading the file indicated. Check for proper software installation.

Failure during Static RAM test on adapter # ’x’

The WAN card bootstrap program encountered an error during the Static RAM test. This indicates that the adapter card may be faulty. Contact your Distributor or Customer Support.

Failure on closure of file <file name>

Failure on file closure <file name>

Failure on write of file <file name>

Failure opening file <file name>

If seen repeatedly, the above messages indicate a problem with your hard drive. Contact your Distributor or Customer Support.

Failure to allocate enough memory for XILINX load file

The WAN card initialization subsystem failed to allocate a buffer for use in downloading files. Restart the system. Report the problem if it continues.

File=l2, Fn=<func name>, err=Layer 2 Error<err msg>, port=<port#>, CES=<link Id>

A Layer 2 error was encountered on the indicated BRI link or port. Your ISDN line (data link) may be going down. If this error condition persists, contact your Distributor or Customer Support. Below are possible error messages and their corresponding definitions:

DISC rcvd

The Network has sent a Layer 2 DISC (Disconnect), terminating the data link. An attempt will be made to re-establish the data link after a switchtype-dependent delay.

DM rcvd

The Network will not allow establishment of the data link at this time. An attempt will be made to re-establish the data link after a switchtype dependent delay.

MDL_ERR_RESP rcvd

The Network has not responded to TEI requests - no data link was established. An attempt will be made to re-establish the data link after a switchtype dependent delay.

rcvd MDL_REM_REQ for TEI <TEI value>

The network has removed the specified TEI, terminating the data link. An attempt will be made to re-establish the data link after a switchtype dependent delay.

File=ME, Fn=_mdl_err, err=Layer 2 Error<err code>rcvd, port=<port#>, CES<link Id>

A Layer 2 error was encountered on the indicated BRI link or port. Your ISDN line (data link) may be going down. If this error condition persists, then report the problem. Below are possible error codes and their corresponding definitions (based on Table 11-1 from CCITT Q.921 specification):

A

The Network sent a RNR (Receiver not Read) or REJ (Reject).

504 CyberSWITCH

Page 504
Image 504
Enterasys Networks CSX5500, CSX6000 manual Failure during read of file ’s’, Failure during Static RAM test on adapter # ’x’