USER’S GUIDE

The conformance selection is prior to CCITT 1988

Verify that the facilities provided by the service provider are CCITT 1988.

The RADIAC Feature is no longer supported. The RADIAC feature has been replaced by the TACACS Feature. The TACACS Feature configuration must be completed before usage.

With the addition of User Level Security, the need for the RADIAC GATEWAY is gone. The CyberSWITCH has incorporated the functionality of the RADIAC GATEWAY within the CyberSWITCH itself. When the configuration file parser encounters a system configured for using the RADIAC feature, it switches the configuration to now use User Level Security utilizing a TACACS off-node authentication server. Since the older CyberSWITCH knew nothing about the location of the TACACS server, the TACACS server configuration must be completed before the CyberSWITCH will allow network access through a WAN connection.

The tone signaling state machine detected an invalid modem revision #

Current modem firmware may not be capable of proper tone signaling. You may need to upgrade your modem firmware. Contact your Distributor or Customer Support.

This card does not support R2 Signaling.

For R2 support, you will need a PRI-23/30 and a DM-24+ or DM-30+. Verify configuration. If you need to upgrade, contact your Distributor or Customer Support.

Timeout detected on connection establishment

The system initiated a connection with a remote site, but a time-out occurred while waiting for a connection response from the network. Verify that the remote site is active and that the network is operational.

Timeout detected on receiving caller’s number

The incoming call security feature is enabled and the caller’s number was not received, so the call was disconnected. Contact your phone company and verify that your switch supports passing along the calling number information element. (This is sometimes referred to as ICLID for InComing Line Identification).

Timeout on SPID Exchange - Slot=<slot#> Port=<port #> Ces=<communication endpoint suffix>

SPID exchange was not completed in time (i.e., switch never responded to the SPID). Check switch configuration to make sure the correct SPID value has been entered.

Timeout on Startup Complete

A startup complete message was not return from the Combinet after we sent the response a number of times. Check the configuration, and then reboot the Combinet. If problem persists, contact your Distributor or Customer Support.

Timeout waiting for DL Config Response

Timeout waiting for DSL Config Response

Timeout waiting for Terminate DSL Response

The above messages indicate that an attempt has been made to dynamically update the Data Link configuration, but the system did not receive a response from a Basic Rate adapter for an earlier request. Restart the system and review the configuration for the adapter. If the problem persists, the indicated adapter card may be faulty. Contact your Distributor or Customer Support.

536 CyberSWITCH

Page 536
Image 536
Enterasys Networks CSX7000, CSX5500 manual Conformance selection is prior to Ccitt, This card does not support R2 Signaling