SYSTEM MESSAGES

System Message Summary

Missing BEARER_CAPABILITY in HOST_CALL_REQUEST

Missing CALLED_NUMBER_IE in HOST_CALL_REQUEST

Missing CHANNEL in HOST_CALL_REQUEST

Missing CHANNEL_ID_IE in HOST_CALL_REQUEST

Missing TN in HOST_CALL_REQUEST

An error has been detected in the R2 or RBS signaling procedure, and will typically result in a failed call. The error was due to unrecognizable or incorrect information. Check configuration; if problem persists, contact your Distributor or Customer Support.

MODEM <modem #> of DM card in slot <slot #> is unusable

An attempt was made to perform an operation on a specific modem that had been deleted from the usable list via the modem delete command. Use the modem add command to make the modem usable again, or use a different modem to perform the desired operation.

MODEM CONNECT failed - connect <connect id # >, board <board # >, modem <modem # >

An attempted modem call has failed to connect. Try reconnecting the call again. If this message consistently appears for the same modem number, contact your distributor or Customer Support.

Modem revision on modem <modem #> of slot <slot # > failed

Individual modems on a Digital Modem card are failing. Check the hardware and software configurations, as well as the seating of the card and the MVIP cabling. If all seems in order, contact your Distributor or Customer Support.

Modem version comparison failed in slot <slot #> due to inconsistent format

This message displays if any of the following files are corrupted: DM56MDM.MOT, DM56PPCU.MOT, DM24MDMU.MOT, DM24PPCU.MOT. Contact your Distributor or Customer Support.

Negotiation Failure with Semipermanent device “x”

There was some problem negotiating a connection with device "x." There was no way to send data. This could be an authentication failure or a PPP failure.

Network loop between site1 and site 2

The system detected a WAN loop between the specified sites, so the System will not forward the duplicate frame. Check the System and network configuration for this loop and adjust.

Network requested init but no SPID configured- Slot=<slot # > Port=<port #> Ces=<communication endpoint suffix>

A SPID is required but is not configured on the indicated line. The configuration of the CyberSWITCH or of the switch should be corrected.

Network sent bad Endpoint identifier - Slot=<slot #> Port=<port #> Ces=<communication endpoint suffix>

During terminal initialization, a bad endpoint identifier was received on the indicated line. This message is informational only; your line should continue to operate normally.

Network sent CAUSE - invalid SPID - Slot=<slot # > Port=<port #> Ces=<communication endpoint suffix>

An invalid SPID is configured on the indicated line. The configuration of the CyberSWITCH or of the switch should be corrected.

Central Site Remote Access Switch 519

Page 519
Image 519