Enterasys Networks CSX7000, CSX5500, CSX6000 Radius RFC2138, Enabling Radius Type Using Cfgedit

Models: CSX7000 CSX6000 CSX5500

1 729
Download 729 pages 41.51 Kb
Page 215
Image 215

CONFIGURING OFF-NODE SERVER INFORMATION

RADIUS RFC2138

VERIFICATION AND DIAGNOSIS

After configuring the RADIUS Accounting Server, connect via a dial-in client, and then disconnect. On the RADIUS Accounting Server, verify that it has received the Accounting Start and Stop message. If it has not, check the CyberSWITCH system log. If there is a message that no response was received from the Accounting Server, then verify your configuration.

To verify configuration, use CFGEDIT and check:

is RADIUS Accounting enabled (Security, Off-node Server Information, Misc options)?

correct IP address (Security, Off-node Server Information, RADIUS Acctng)?

correct shared secret?

correct UDP port number?

To determine if you have communications with the RADIUS Accounting Server, issue the IP ping x.x.x.x command, where x.x.x.x is the RADIUS Accounting Server’s address.

If this test fails on occasion, yet is successful at other times, it may be that the connection between the CyberSWITCH and the RADIUS Accounting Server is inadequate to provide reasonable accounting information.

RADIUS RFC2138

In addition to the Cabletron implementation of RADIUS (which supports dialout), the CyberSWITCH also supports an RFC2138-compliant implementation. If you are using an RFC2138 RADIUS, be sure to enable this RFC2138 implementation.

ENABLING RADIUS TYPE

USING CFGEDIT

1.From CFGEDIT Main Menu, select (3) Security.

2.Select (5) Off-node Server Information.

3.Select Misc Off-node Server Options. A screen similar to the following will display current settings:

Misc Off-node Server

Options Menu:

 

 

 

 

Current Settings

1)

Radius Accounting (Enable/Disable)

Enabled

2)

Radius Type (RFC2138/Cabletron)

RFC2138 compliant

3)

Dynamic Device

Option (Enable/Disable) Enabled

4)

Dynamic Device

Default Settings

 

Select function from

above or <RET> for previous menu:

4.Check the current setting for Radius type.

Note: This selection toggles back and forth. If the current setting is RFC2138 compliant, you will enable the Cabletron implementation by selecting Radius Type. If you select Radius Type again, you will return the function to RFC2138 compliance.

5.Press <RET> to return to the previous menu.

Central Site Remote Access Switch 215

Page 215
Image 215