CONFIGURING CALL CONTROL

CSM as a Call Control Manager

CSM AS A CALL CONTROL MANAGER

This feature allows you to use the CSM for call control management only. This feature allows you to continue to use other authentication servers (e.g., RADIUS, ACE) yet still gain the benefits of CSM call control management.

CONFIGURING CSM FOR CALL CONTROL

USING CFGEDIT

1.Select CSM as Call Control Manager from the Call Control Options menu.

2.The current status of the CSM Call Control Server will be displayed. Select 1 to toggle between enabled and disabled, and ensure an enabled setting.

3.Select TCP port number if you wish to change this setting. Changes here will also appear on the CSM Authentication menu.

4.Return to the Main Menu.

5.For authentication, if you are using the On-node Device Table or Off-node Device Level Security, you are finished with the configuration of this feature. If you are using User Level Security, you may wish to adjust the Authentication Time-out and/or change the Call Control Failure banner. Continue with the following steps.

6.Select Security and then Network Login Information.

7.Select Network Login General Configuration.

8.Select Authentication Timeout. Follow on-screen instructions to adjust this value.

9.Return to the Network Login Information Menu and select Network Login Banners.

10.Select the Call Control Failure Banner. Follow on-screen instructions to adjust this banner.

Note: If you are using CSM as your authentication manager, you do not have to configure the call control option separately. This is only necessary when you are configuring another device for authentication, and wish to use CSM for call control only.

CONFIGURATION ELEMENTS

STATUS

Allows you to enable or disable CSM for call control management.

TCP PORT NUMBER

The TCP port number used by CSM. Note that you can assign a user-defined port number, but that the CSM TCP port number must be entered identically on both the CyberSWITCH and CSM.