SYSTEM MESSAGES

System Message Summary

B, D

The Network sent a DM(F=1) or a UA and will not allow establishment of the data link at this time. An attempt will be made to re-establish the data link after a switchtype dependent delay.

C

The Network sent an unsolicited UA and will not allow establishment of the data link at this time. An attempt will be made to re-establish the data link after a switchtype dependent delay.

E

The Network sent a DM(F=0). The data link will be restarted immediately.

F

Network restarted data link.

H

Timeout on sending DISConnect to the Network. Unable to bring up data link. An attempt will be made to re-establish the data link after a switchtype dependent delay.

I

Timeout sending I(Info) frame to the Network. The data link will be restarted immediately.

J

The Network sent a Layer 2 frame with an incorrect receive sequence number (Nr).

K

The Network sent a FRMR (Frame Reject) response. The data link will be restarted immediately.

L

The Network sent a Layer 2 frame with a control field error. This is typically an unimplemented frame.

M

The Network sent a Layer 2 frame with an illegal Info field.

N

The Network sent a Layer 2 frame with an incorrect length.

O

The Network sent a Layer 2 frame that was too long.

U

The Network sent a Layer 2 frame with a control field error. Typically an unknown frame.

Central Site Remote Access Switch 505

Page 505
Image 505
Enterasys Networks CSX6000, CSX5500, CSX7000 manual Central Site Remote Access Switch