TRACE MESSAGES

Call Trace Messages

In - PROGRESS Call Id=<call Id> Slot=<slot #> Port=<port #> Chans=<bearer channel map> CauseLoc=<cause location> Cause=<cause value> Signal=<signal value> ProgLoc=<progress location> Prog=<progress value> Ces=<communication endpoint suffix> ConnId=<connect Id>

The system has received a call progress message from the network. This is usually received in response to sending a call request. The <parameters> are included for your Distributor or Cabletron Customer Support. Refer to the Cause Codes Table for more information.

In - REJECTION Call Id=<call Id> Slot=<slot #> Port=<port #> Loc=<location> Cause=<cause value> Ces=<communication endpoint suffix> ConnId=<connect Id>

The system has received a call rejection message from the network. This is in response to sending a call request. The Call Id and Ces values are included for your Distributor or Cabletron Customer Support. The remaining parameters are used to report line details. Refer to the Cause Codes Table for more information.

Interworking unspecified cause

Informational call trace message. This message is used to indicate additional details on the <cause value> received in the call progress information message. Refer to the Cause Codes Table for more information.

Off-hook warning tone on

Informational call trace message.

Origination call address is non-ISDN

Informational call trace message.

Out - ALERTING Call Id=<call Id> Slot=<slot #> Port=<port #> Chans=<bearer channel map> The system is sending a connection to the network. This is sent in response to receiving a call indication. The <parameters> are included for your Distributor or Cabletron Customer Support.

Out - BRD CFG Slot=<slot # >

The system is initializing the indicated adapter.

Out - CALL RQST ACK Call Id=<call Id> Rate=<data rate> Slot=<slot # > Port=<port #> Chans=<bearer channel map> TN=<telephone number dialed> Ces=<communication endpoint suffix> ConnId=<connect Id>

The system is sending a call request to the network. The Call Id and Ces values are included for your Distributor or Cabletron Customer Support. The remaining parameters are used to report line details.

Out - configure <port # >

The system is initializing the indicated line adapter.

Out - CONNECT Call Id=<call Id> Slot=<slot # > Port=<port #> Chans=<bearer channel map> Ces=<communication endpoint suffix> ConnId=<connect Id>

The system is sending a connection to the network. This is sent in response to receiving a call indication. The <parameters> are included for your Distributor or Cabletron Customer Support.

Out - DISCONNECT Call Id=<call Id> Slot=<slot #> Port=<port #> Cause=<cause value> Ces=<communication endpoint suffix> ConnId=<connect Id>

The system is sending a disconnect to the network to terminate a call. The Call Id and Ces values are included for your Distributor or Cabletron Customer Support. The remaining parameters are used to report line details. Refer to the Cause Codes Table for more information.

Central Site Remote Access Switch 549

Page 549
Image 549
Enterasys Networks CSX5500 Interworking unspecified cause, Off-hook warning tone on, Origination call address is non-ISDN