CONFIGURING OTHER ADVANCED OPTIONS

Default Line Protocol

PPPLink Failure Detection can be enabled or disabled within the PPP Options configuration menu. When enabled, two other configurable parameters then control the mechanism. Upon entrance of a PPP link into Network Phase (the point at which device data transfer is allowed), Echo-Requests will be sent at a configured frequency. As long as Echo-Replies are received, the link is deemed to be functional.

A second parameter specifies the maximum number of Echo-Request attempts which will be transmitted without a reply. If this limit is reached, a message is logged and the link is reported as faulty. Thus, the configured frequency multiplied by the configured maximum attempts yields the approximate time it will take to detect a failed link.

Note: Within the CyberSWITCH, there are certain accesses which also present the ability to enable/disable the periodic transmission of link maintenance type packets. For example, the packet-based Frame Relay access supports the configurable enable/disable of “Keepalives” in order to avoid the extra per-packet costs which the periodic Echo-Request frames might incur. The PPP Link Detection Failure feature will honor such access-based configuration, in addition to the explicit enable/disable configuration status of the PPP feature itself.

PPPREFERENCE DOCUMENTS

Point-to-Point Protocol (PPP) is also described in more detail in the set of RFCs listed below:

RFC 1661 The Point-to-Point Protocol

RFC 1638 PPP Bridging Control Protocol (BCP)

RFC 1549 PPP in HDLC Framing

RFC 1547 Requirements for an Internet Standard Point-to-Point Protocol

RFC 1334 PPP Authentication Protocols

RFC 1332 The PPP Internet Protocol Control Protocol (IPCP)

DEFAULT LINE PROTOCOL

The default values for this feature are adequate for most situations. Instructions are included for the rare instance that you need to alter the configuration.

Note: This feature does not apply to analog connections (including digital modem).

CONFIGURING DEFAULT LINE PROTOCOL

USING CFGEDIT

1.Select Default Line Protocol from the Options menu.

2.Change the action on the frame timeout.

3.Change the frame timeout value.

Central Site Remote Access Switch 399

Page 399
Image 399
Enterasys Networks CSX5500, CSX6000, CSX7000 manual Configuring Default Line Protocol Using Cfgedit