HARDWARE INSTALLATION

Adapter Settings

ENCRYPTION ADAPTER SETTINGS

DES/RSA Adapter

The DES/RSA adapter is available in the United States and Canada only. The adapter has a set of eight dip switches in a switch block labelled SW1. Set these dip switches to map the encryption adapter memory at D800:

SW1 Memory Mapped Address

1

2

3

4

5

6

7

8

 

 

 

 

 

 

 

 

 

D800

OFF

OFF

OFF

OFF

OFF

OFF

OFF

ON

 

 

 

 

 

 

 

 

 

The adapter has one jumper (J1), which must be installed!

MVIP SETTINGS

The following adapters have MVIP connectors:

PRI-23,

PRI-23/30,

DM-8,

DM-24,

DM-24+, and

DM-30+

In order to establish an MVIP bus, follow this process:

1.First, select slots for all MVIP adapters. If you are using both PRI and DM adapters, begin with a PRI adapter, and then select slots alternating PRI and DM adapters as described in Selecting Slots for Adapters.

2.Next, terminate the MVIP jumpers on both the first and last adapter in the MVIP adapter series. (All other MVIP jumpers on the adapters between these two should be left unterminated).

To terminate the MVIP bus for the PRI-23, place the jumpers vertically on JP9.

To terminate the MVIP bus for the PRI-23/30, place the jumpers vertically on JP9.

To terminate the MVIP bus for the DM-8, place jumpers horizontally on J5 and J6.

To terminate the MVIP bus for the DM-24, turn switch blocks S1 and S4 “ON”.

Note: DM-24 adapters may have either toggle or slide switches. In either case, the switch is “ON” if it is toggled or slid to the right. All four switches should always be set in the same direction.

To terminate the MVIP bus for the DM-24+or the DM-30+, place the four switches in switch block SW5 to the “ON” position.

3.Install MVIP adapters into pre-selected slots.

4.Install MVIP ribbon cable. Refer to Connecting Adapter Inter-board Cables.

5.Install TDM ribbon cable. Refer to Connecting Adapter Inter-board Cables

In order to improve signal quality (which in turn results in higher modem-connection rates), you should terminate the MVIP bus at both ends as recommended in step (2). However, not all system configurations support this. Note that PRI-8, PRI Expansion and BRI boards do not support MVIP termination.

Note: MVIP termination at both ends (step 2) also applies to six PRI-23/30 configurations.

Central Site Remote Access Switch 89

Page 89
Image 89
Enterasys Networks CSX7000, CSX5500, CSX6000 manual Encryption Adapter Settings, DES/RSA Adapter, Off, Mvip Settings