Exploring the Utilities
Figure 3-4. RAID Firmware Download Successful
Intel (R) Integrated RAID - Firmware Update Utility
Copyright(c) Intel Corporation
RAID Firmware download successful.
Please reboot the system now to use the new firmware.
3.2.1.4Advanced RAID Configuration Utility
The Advanced RAID Configuration Utility (RCU)is used to create and configure multiple volumes before installing the operating system. See Section 2.4, “Advanced RAID Configuration Utility for complete instructions for starting and working in Advanced RCU.
3.2.1.5RAID Recovery (Recover Flash)
The RAID Recovery utility (RRU) erases and writes a new binary image in the flash memory of SRCU31 hardware. Note that this procedure requires that you manually open the server and change jumper settings. The RRU requires that the array and volumes are in a normal status. Figure
Figure 3-5. RAID Firmware Recovery Overview
Discover
Bad Firmware
Flash Memory
is corrupted
Set Jumpers
to
Flash Mode
Download
the Firmware
Image
from
Reset Jumper
to Normal
Operating
Mode
Follow the procedure below to flash the SRCU31 hardware.
1.Back up the data from the disk connected to the SRCU31 adaptor before recovering the firmware to flash memory.
2.Set the Jumpers to Flash Mode
To reprogram the SRCU31 hardware, you must change jumper settings.
If you are using the SRCU31 adapter card, change the jumper settings as follows:
a. Take all precautions to prevent ESD damage before handling the SRCU31 adapter card.
Intel® Server RAID Controller |