Intel SRCU31 user manual 2.3.3.5Create a RAID 5 Volume with 3 Disks, Advanced Installation Steps

Models: SRCU31

1 184
Download 184 pages 31.45 Kb
Page 33
Image 33
Figure 2-6. Create RAID 1 Volume

Advanced Installation Steps

Figure 2-6. Create RAID 1 Volume

Intel(R) Integrated RAID - RAID Configuration Utility Version 4.05

Copyright(c) Intel Corporation 1998-2000 All Rights Reserved

RAID 1 Volume Creation

Enter the name of the RAID Volume:

Volume1

 

 

 

Enter the size of the

RAID Volume:

8582

 

 

 

Maximum RAID

Volume Size:

8582

 

 

 

Create with Hot Spare? *YES

NO

 

Is this the

Boot Device? *YES

NO *YES

NO

SUBMIT

Arrow Keys to Highlight, ENTER to Select.

Esc for previous menu

Select Submit. The RAID 1 confirmation screen appears. If you are satisfied with the selections you have made for your RAID 1 volume, select Yes in the confirmation screen and the volume creation process begins.

2.3.3.5Create a RAID 5 Volume (with 3 Disks)

Figure 2-7shows the RAID 5 volume creation screen with 3 SCSI disks available.

Naming the RAID Volume

In Figure 2-7, RAID 5 volume is named Volume1. By default, the first RAID volume name will always appear as Volume1. You are free to rename the RAID volume providing it starts with an alpha character between A and Z in upper or lower case and does not exceed the 15 character limit. The name may include an “_” (underscore) character. Rename the existing volume name if needed.

Choosing the Size of the RAID Volume

In Figure 2-7, the maximum volume size available (by default the maximum size always appears), 12873, has been selected. Another way to allocate the maximum size available to a RAID volume is to enter a size value of 0. A value of 0 will automatically allocate all available space to a new RAID volume. Enter the appropriate volume size.

Choosing the RAID Volume as a Boot Device

In Figure 2-7,the RAID 5 Volume being created is selected by default to become the boot device. To select the RAID 5 Volume as a boot device select Yes, or select No to create the volume without selecting it as the boot device. For more information about selecting a boot device see

Section 2.3.4.3. The RAID 5 confirmation screen appears.

Intel® Server RAID Controller U3-1 User’s Manual Rev 1.0

2-9

Page 33
Image 33
Intel SRCU31 user manual 2.3.3.5Create a RAID 5 Volume with 3 Disks, Advanced Installation Steps, 6.Create RAID 1 Volume