Hardware Details
A.2.2 | Intel® Server RAID Controller | ||
Table |
| ||
|
|
|
|
|
| Component | Feature |
|
|
|
|
|
|
| Intel i960® RN I/O Processor, 100MHz, RISC |
|
| CPU | controller features hardware XOR support for highspeed RAID |
|
|
| 5 parity calculations. |
|
|
|
|
|
| Memory/Cache | 3.3V, unbuffered PC100, ECC, SDRAM DIMM expandable to |
|
| 32, 64 or 128MB | |
|
|
| |
|
|
|
|
|
| Cache | Downstream Write Through, Full and Sequential |
|
| Selectable per volume. | |
|
|
| |
|
|
|
|
|
| Firmware | ROM Type, Flash EEPROM, 2MBits x 8 (flashable) |
|
|
|
|
|
| PCI | Transfer Rate: 264MB/second Burst |
|
|
|
|
|
| Voltages | +12V, +5V and 3.3V (all +/- 5%) |
|
|
|
|
|
| Array Interface to Host | Interface to Host PCI 2.2 |
|
|
|
|
|
| PCI Signaling | Capable of being used in a 5 volt or 3.3 volt slot. |
|
|
|
|
Table |
| ||
|
|
|
|
|
| Attribute | Conditions |
|
|
|
|
|
| Temperature | Operating 0° to +55° C |
|
| Storage | |
|
|
| |
|
|
|
|
|
| Humidity | Operating 90% relative humidity |
|
| Storage 90% relative humidity | |
|
|
| |
|
|
|
|
|
| Form Factor | Length 6.75 inches |
|
| Height 4 inches | |
|
|
| |
|
|
| |
Table |
| ||
|
|
|
|
|
| SCSI Controller Supported | Description |
|
|
|
|
|
| SCSI Controller: LSI SYM53C1010 | LSI Ultra160 SCSI Controller |
|
|
| |
A.3 | Disk Drive Connectivity | ||
A.3.1 | SCSI Specifics |
| |
|
| This section provides information on supported SCSI technology and form factors. | |
A.3.1.1. | Drives Supported |
| |
|
| SRCU31 supports up to 15 SCSI devices. It supports up to 15 disks (or 14 disks if one of the SCSI | |
|
| ID’s is occupied by an Intelligent SCSI Enclosure). |
Intel® Server RAID Controller |