PRESET
SAVE
09.95
Siemens AG 2001 All Rights Reserved 6FC5197jAA50

4–36

SINUMERIK 840C (IA)
With a main memory capacity of 16 MB the mutual exclusion of certain applica-
tions can be cancelled.
This is the case for the mutual exclusion of the optional applications WOP and
SIMULATION.
To cancel the exclusion of WOP, the following lines have already been inserted in
the BEDCONF file:
/ / a 2 1 107 11’’12’’13’’0’’0’ \
/ / ’0’’0’’0’’0’’0’ \
/ / ’0’’0’’0’’0’’0’ //TermiWOP
/ / a 2 1 114 11’’12’’13’’0’’0’ \
/ / ’0’’0’’0’’0’’0’ \
/ / ’0’’0’’0’’0’’0’ //TermiSimu-
lation
These lines are marked as comments by the characters // at the beginning of the
line and therefore have no effect.
To activate them, remove the comment characters and place them in front of the
three immediately preceding lines instead.
Because it is only possible to process the file in the user branch, the file BED-
CONF is copied there by Preset.

4.4.3.2 Configuring file BEDCONF in directory OPERATION/PROGRAM

Example The text in the toggle fields for the screen form channel information for setting the
wait marks is configured in the BEDCONF file (variable a 45232).
OK
Paste from
clipboard
Undo
>>
 
 
 
     
Channel
Type
m
Nubmer
   
Fig. 4.15
With the PRESET softkey, the file is copied to the user branch where it can be
edited with the ASCII editor.
!Caution
Any errors in this file can lead to system failure.
Any text of maximum 10 characters can be entered in line 37 between the
speech marks.
Any changes made are stored on the hard disk using the SAVE softkey.
4 MMC Area Diagnosis
4.4.3 BEDCONF configuration file