Chapter 2 Avaya C460 CLI Commands
sync spv
User level: read-write, admin.
Use the sync spv command to synchronize the following between an Active Supervisor Module and Halted Supervisor Module:
•Boot bank
•Firmware images
•Device manager image
You can only execute this command from the active Supervisor Module CLI.
The syntax for this command is:
sync spv
The synchronization may take up to 90 seconds to complete.
Example:
C460-1(super)# sync spv
This command may overwrite the neighbor SPV software and reset it
***Confirmation *** - do you want to continue (Y/N)? y Copying Bank A to the neighbor SPV ...
Copying Bank A to the neighbor SPV done Copying Bank B to the neighbor SPV ...
Copying Bank B to the neighbor SPV done
Copying Embedded Web image to the neighbor SPV ...
Copying Embedded Web image to the neighbor SPV done Setting boot bank of the neighbor SPV ...
Setting boot bank of the neighbor SPV done Setting chassis sync on for the neighbor SPV...
Setting chassis sync on for the neighbor SPV done SPVs are resetting.
Please wait till the process is finished. The SPVs will be synchronized after the reset is completed
The configuration is synchronized after you perform a reset.
tech
Use the tech command to enter tech mode. This command is reserved for service personnel use only.
224 | Avaya C460 Reference Guide |