Chapter 2 Avaya C460 CLI Commands

The syntax for this command is:

set port redundancy-intervals <min-time-between-switchovers><switchback-interval> none

min-time-between-switchovers

The minimum time between redundancy

 

switchovers for each pair (in milliseconds).

switchback-interval

The period the primary port link has to be

 

“up” before the system switches back (in

 

milliseconds).

 

• If switchback interval is zero, the system

 

never switches back

 

• If it is one, switchback occurs immediately

 

after the primary port link returns

none

The system switches bank only if the

 

secondary link fails.

Example:

 

C460-1#set port redundancy-intervals 100 20

Done!

set port spantree

User level: read-write, admin.

Use the set port spantree command to enable or disable the spanning tree mode for specific switch ports.

The syntax for this command is:

set port spantree {enabledisable} [module/port]

enabledisable

Enables or disables the spanning tree mode for the

 

specified ports.

Module

Module number

Port

Port number

Example:

 

C460-1#set port spantree enable 3/1

port 3/1 was enabled on spantree

116

Avaya C460 Reference Guide

Page 128
Image 128
Avaya manual C460-1#set port redundancy-intervals 100, Set port spantree, C460-1#set port spantree enable 3/1