Chapter 2 Avaya C460 CLI Commands
port | Number of the port on the module. If you do not specify a |
(optional) | number, all the ports on the module are shown. |
| You can also specify a range of ports separated by a dash, for |
| example, |
Example to show PoE configuration on I/O module 3:
|
| |||
Port | Inline |
|
| Powering |
| Operational |
| Priority | |
| Status |
|
|
|
3/1 | Fault |
|
| Low |
3/2 | Fault |
|
| Low |
3/3 | Fault |
|
| Low |
3/4 | Searching |
|
| Low |
3/5 | Searching |
|
| Low |
3/6 | Searching |
|
| Low |
3/7 | Searching |
|
| Low |
Output fields: |
|
|
| |
Field |
| Description |
| |
Inline operational | • | Disabled – Detection process in administratively | ||
status |
|
| disabled |
|
|
| • Searching – No PD connected | ||
|
| • Delivering power – Valid PD connected and | ||
|
|
| power delivered on the port | |
|
| • Fault – Invalid PD connected | ||
Powering Priority | • | Critical |
| |
|
| • | High |
|
|
| • | Low |
|
show powerinline budget
User level:
Use the show powerinline budget command to display the PoE budget distribution for modules in the switch. The budget assigned for the module includes power for PoE ports and power required for module basic PoE operation.
Avaya C460 Reference Guide | 199 |