Chapter 2 Avaya C460 CLI Commands

port

Number of the port on the module. If you do not specify a

(optional)

number, all the ports on the module are shown.

 

You can also specify a range of ports separated by a dash, for

 

example, 4/5-13 for ports 5 to 13 on module 4.

Example to show PoE configuration on I/O module 3:

C460-1>show powerinline 3

 

Port

Inline

 

 

Powering

 

Operational

 

Priority

 

Status

 

 

 

------

------------------

---------

3/1

Fault

 

 

Low

3/2

Fault

 

 

Low

3/3

Fault

 

 

Low

3/4

Searching

 

 

Low

3/5

Searching

 

 

Low

3/6

Searching

 

 

Low

3/7

Searching

 

 

Low

Output fields:

 

 

 

Field

 

Description

 

Inline operational

Disabled – Detection process in administratively

status

 

 

disabled

 

 

 

• Searching – No PD connected

 

 

• Delivering power – Valid PD connected and

 

 

 

power delivered on the port

 

 

• Fault – Invalid PD connected

Powering Priority

Critical

 

 

 

High

 

 

 

Low

 

show powerinline budget

User level: read-only, read-write, admin.

Use the show powerinline budget command to display the PoE budget distribution for modules in the switch. The budget assigned for the module includes power for PoE ports and power required for module basic PoE operation.

Avaya C460 Reference Guide

199

Page 211
Image 211
Avaya manual C460-1 show powerinline, Show powerinline budget