Chapter 2 | Avaya C460 CLI Commands |
|
| Output fields: |
|
| Field | Description |
| Spanning tree | |
| Designated root | MAC address of the designated |
|
| bridge |
| Designated Root | Priority of the designated root bridge. |
| Priority |
|
| Designated Root Cost | Total path cost to reach the root. |
| Designated Root Port | Port through which the root bridge can be reached |
|
| (shown only on non root bridges) |
| Root Max Age | Amount of time a BPDU packet should be considered |
|
| valid |
| Hello Time | Number of times the root bridge sends BPDUs |
| Bridge ID MAC ADDR | Bridge MAC address used in the sent BPDUs |
| Bridge ID Priority | Bridge Priority |
| Port | Port number |
| ||
|
| connected, blocking, listening, learning, forwarding, |
|
| bridging, or |
| Cost | Cost associated with the port |
| Priority | Priority associated with the port |
show spv
User level:
Use the show spv command to display the following information about supervisor modules:
• Chassis MAC address
• SPV status – active, standby, halted.
• Indication whether the SPV’s are synchronized.
• Software version of the two image banks.
The syntax for this command is: show spv