Chapter 6 Cisco ASR 1002 Router Overview and Installation

Cisco ASR 1002 Router Description

Table 6-2

Cisco ASR 1002 Router AC Power Supply LEDs

 

 

 

 

 

 

LED Label

 

LED

Color

Description

 

 

 

 

 

INPUT OK

 

Power supply activity

Green

LED is green and signals that the AC power supply input

 

 

 

 

voltage is greater than 85V.

 

 

 

 

 

 

 

 

None

If LED is not lighted, the AC input voltage is less than

 

 

 

 

70V or the power supply is turned off. For an AC input

 

 

 

 

voltage between 70V and 85V the INPUT OK LED can be

 

 

 

 

either on, off, or flashing

 

 

 

 

 

FAN OK

 

Power supply fan activity

Green

The LED is illuminated green when all fans are

 

 

A bi-color LED indicates

 

operational.

 

 

 

 

 

 

fan status.

Red

The LED is illuminated red when a fan failure is detected.

 

 

 

 

 

OUTPUT FAIL

 

Power supply activity

Red

LED is red. It is off to signal that the DC output voltages

 

 

 

 

are within the normal operating range. Output voltage

 

 

 

 

between the minimum and maximum limits will not

 

 

 

 

create an output fail alarm and output voltages below the

 

 

 

 

minimum or above the maximum will create an output fail

 

 

 

 

alarm.

 

 

 

 

 

Figure 6-5shows the AC Power Supply for the Cisco ASR1002 Router.

Figure 6-5 AC Power Supply for the Cisco ASR 1002 Router

1

2

3

4

5

6

OUTPUT

 

FAN

OUTPUT INPUT

FAN

FAIL

OK

OK

FAIL

OK

OK

0

This unit might have more than

This unit might have more than

one power supply connection.

one power supply connection.

 

All connections must be removed

All connections must be removed

 

to de-energize the unit.

to de-energize the unit.

 

1

280288

 

 

8

7

 

1

Chassis ESD socket

5

AC power supply fan

 

 

 

 

2

AC power supply slot number 0

6

AC power supply captive installation screw

 

 

 

 

3

AC power supply On (I) /Off (O) switch

7

AC power supply slot number 1

 

 

 

 

4

AC power supply LEDs

8

AC power supply inlet

 

 

 

 

DC Power Supply for Cisco ASR 1002 Router

The DC power supply input connector is a euro-style terminal block and is compliant to all safety agencies and electrical requirements of the supply. The DC power supply operates within specification from –40.5VDC to –72VDC continuously once the power supply DC input turn on threshold of –43.5V has been reached.

Cisco ASR 1000 Series Aggregation Services Routers Hardware Installation and Initial Configuration Guide

 

OL-13208-03

6-7

 

 

 

Page 167
Image 167
Cisco Systems ASR 1000 Series manual DC Power Supply for Cisco ASR 1002 Router