Chapter 8 Replacing Cisco ASR 1000 Series Routers
Removing and Replacing a DC Power Supply in Cisco ASR 1004 Router
Removing the DC Power Supply From Cisco ASR 1004 Router
Before you can remove a DC power supply from the Cisco ASR 1004 Router, you must remove power from the power supply. Follow these steps to remove power and the DC power supply from the chassis.
Step 1 Make certain that the chassis ground is connected before you begin removing the DC power supply. Step 2 Switch the power supply circuit breaker switch to Off (O).
Step 3 Locate the terminal block on the rear of the chassis on the power supply. Figure
Step 4 Remove the slotted plastic cover from the terminal block.
Figure 8-25 Cisco ASR 1004 Router DC Power Supply Terminal Block
1 2 3 4
4
280188
1 | Negative terminal | 3 | Earth ground stud |
|
|
|
|
2 | Positive terminal | 4 | Terminal block plastic cover screws |
|
|
|
|
a.Loosen and remove the two #10 screws from the plastic cover. The plastic cover has slots that help to slide it out towards the right.
b.Using a nut driver (7/16 size), unscrew the positive kepnut, positive cable, and the flat washer, in that order. The terminal block houses two
c.Follow Step 4b and remove the negative cable.
|
| Cisco ASR 1000 Series Aggregation Services Routers Hardware Installation and Initial Configuration Guide |
|
| |
|
|
| |||
|
|
|
|
| |
|
|
|
|