Chapter 8 Replacing Cisco ASR 1000 Series Routers Field-Replaceable Units

Removing and Replacing a Cisco ASR 1004 Router Power Supply

Figure 8-22 Cisco ASR 1006 Router DC Power Supply Terminal Block Plastic Cover and Switch

1

 

 

 

OFF

 

 

 

55

-

 

 

 

48/-60V

40A

280026

2

1

DC power supply On/Off switch

2

Terminal block plastic cover black screw

Step 12 Remove the tape from the circuit-breaker On/Off switch.

Step 13 Switch the circuit breaker On/Off switch to the On () position.

Note The requirement for maximum torque applied to the power or ground Kepnuts must be 8 in-lb when the power or ground lug is not present.

This completes the procedure for installing the DC power supply into the Cisco ASR 1006 Router.

Removing and Replacing a Cisco ASR 1004 Router Power Supply

This section provides information about removing and replacing the following power supplies in a Cisco ASR 1004 Router:

AC power supply

DC power Supply

Removing the AC Power Supply from Cisco ASR 1004 Router

Because of the power supply redundancy, there is no need to power off the Cisco ASR 1004 Router before removing one of the AC power supplies.

 

 

Cisco ASR 1000 Series Aggregation Services Routers Hardware Installation and Initial Configuration Guide

 

 

 

 

 

 

OL-13208-03

 

 

8-31

 

 

 

 

 

Page 237
Image 237
Cisco Systems ASR 1000 Series manual Removing and Replacing a Cisco ASR 1004 Router Power Supply