2-33
Cisco ASR 1000 Series Aggregation Services Routers Hardware Installation and Initial Configuration Guide
OL-13208-03
Chapter 2 Cisco ASR 1000 Series Routers Components
Cisco ASR 1000 Series Router Power Supplies
DC Power System Input for Cisco ASR 1002
The DC power supply operates within specification from –40.5VDC to –72VDC con tinuously once the
the power supply DC input turn on threshold of –43.5V has been reached. Tab le 2-21 shows the common
input ranges for referenc e only. The DC power input connector is a euro-style terminal block that accepts
three wires, one positive, one negative, and one grounding wire.
DC Power System Output for Cisco ASR 1002
The DC power supply output tolerance is defined in Tab le 2-22 under all combinations of DC input line
variation. Total system power consumption should not exceed 470 watts or output rating of each power
supply.
Note Two power supplies are used for redundant operation. System total power consumption shall never
exceed rating of one power supply to maintain redundancy.
Tab l e 2-21 Cisco ASR 1002 Router DC Power System Input
Voltage Range (VDC) Minimum Nominal Maximum
Domestic –40.5 –48 –56
International –55 –60 –72
Tab l e 2-22 Cisco ASR 1002 Router DC Power System Output Voltage and Current
Output Voltage +12 VDC +3.3 V
Minimum –11.80 VDC –3.20 VDC
Nominal –12.00 VDC –3.30 VDC
Maximum –12.20 VDC –3.40 VDC
Output Current
Minimum –2.0 A –0.10 A
Maximum –39 A –3.125 A