Chapter 8 Replacing Cisco ASR 1000 Series Routers
Removing and Replacing a Cisco ASR 1002 Router Power Supply
Caution If you remove a power supply, the system can run for a maximum of five minutes before the system shuts down. The fans and power elements are independent within the power supply. Therefore, it is not required that the replacement power supply be energized within five minutes. The only requirement is that the power supply be installed in the chassis, which energizes the fans and maintains proper system cooling.
Step 4 Grasping the power supply handles, pull the power supply from the chassis.
Step 5 Replace the AC power supply within five minutes.
This completes the procedure for removing the AC power supply from the Cisco ASR1002 chassis.
Replacing the AC Power Supply in Cisco ASR 1002 Router
This section provides information about installing an AC power supply in the Cisco ASR 1002 Router.
Warning Never install an AC power module and a DC power module in the same chassis. Statement 1050
Step 1 Insert an AC power supply in power supply slot 0 or power supply slot 1 until it is fully seated. Step 2 Tighten the captive screws.
To connect AC power to the Cisco ASR 1002 Router, follow these steps:
Step 1 At the rear of the router, check that the power switch is in the Off (O) position.
Note Turn the power switch to the On (I) position after both power sides of the power cord are connected.
Step 2 Insert the AC power cable into the AC power inlet and then turn On (I).
Step 3 To ensure that the AC power cord does not interfere with other cables or wires, dress the AC power cable in one of the following ways.
a.Leave a small service loop in the AC power cord from the inlet and then secure the power cord through the AC power supply handle as shown in Figure
|