Chapter 7 Cisco ASR 1000 Series Routers Power Up and Initial Configuration

Verifying Power Supply Operation

You have selected passwords for access control.

Captive installation screws are tight on all removable components.

The console terminal is turned on.

You have determined the IP addresses for the Ethernet and serial interfaces.

Empty card slots or card bays are filled with card blanks. This ensures proper air flow through the chassis and electromagnetic compatibility (EMC).

You are now ready to start your router.

Verifying Power Supply Operation

Follow this procedure to verify power supply is operating correctly.

Step 1 Check that the power supply LEDs are:

INPUT OK is green

FAN OK is green

OUTPUT FAILED is not illuminated

Step 2 To ensure that the power supply state is OK, type the show platform command. This output sample is from a Cisco ASR1006 router. The other Cisco ASR1000 routers display similar type of output.

MCP_SCAL_R1#sho plat

Chassis type: ASR1006

The following output displays:

Slot

Type

State

Insert Time

1

ASR1000-SIP10

ok

00:03:19

1/1

SPA-8X1GE-V2

ok

00:02:23

2

ASR1000-SIP10

ok

00:03:19

2/0

SPA-1X10GE-L-V2

ok

00:02:22

2/1

SPA-8X1GE-V2

ok

00:02:17

R0

ASR1000-RP1

ok,active

00:03:19

F0

ASR1000-ESP20

ok,active

00:03:19

P0

ASR1006-PWR-AC

ok

00:02:50

P1

ASR1006-PWR-AC

ps, fail

00:02:50

Slot

CPLD Version

Firmware

 

 

 

Version

 

1

07091401

12.2(33r)XN2

2

07091401

12.2(33r)XN2

R0

08060301

12.2(0:0)

 

F0

08041102

12.2(33r)XN2

MCP_SCAL_R1#

If the LEDs indicate a power problem or the power supply state is ps,fail, then contact a customer service representatives for assistance or additional instructions.

Cisco ASR 1000 Series Aggregation Services Routers Installation and Initial Configuration Guide

7-2

OL-13208-03

 

 

Page 198