Chapter 8 Replacing Cisco ASR 1000 Series Routers
Removing and Replacing a SPA Interface Processor
Removing a SPA Interface Processor
To remove a SPA Interface Processor (SIP), follow these steps.
Step 1 Slip on the
Step 2 Using the handles on both sides of the module, with two hands gently slide the Cisco ASR 1000 Series SPA Interface Processor out of the chassis slot.
Note Handle the Cisco
Step 3 Place the Cisco
For detailed information about installing and removing SIPs and SPAs, see the Cisco ASR 1000 Series Aggregation Services Routers SIP and SPA Hardware Installation Guide.
You have completed the removal procedure for the Cisco
Replacing a SPA Interface Processor
To replace a SPA Interface Processor (SIP), follow these steps.
Step 1 Before inserting a SIP, make sure that the chassis is grounded.
Step 2 To insert the SIP, carefully align the edges of the SIP between the upper and lower edges of the router slot.
Step 3 Carefully slide the SIP into the router slot until the SIP makes contact with the backplane. Step 4 Tighten the locking thumbscrews on both sides of the SIP.
Step 5 Connect all cables to each SPA.
Removing a Shared Port Adapter From a SIP
To remove a shared port adapter (SPA), follow these steps.
Step 1 Attach an ESD wrist strap between you and an unpainted chassis surface.
Step 2 Shut down the interface so that there is no traffic running through the shared port adapter when it is removed.
Caution Removing a shared port adapter while traffic is flowing through the ports can cause system disruption.
|
| Cisco ASR 1000 Series Aggregation Services Routers Hardware Installation and Initial Configuration Guide |
|
| |
|
|
| |||
|
|
|
|
| |
|
|
|
|