Chapter 6 Cisco ASR 1002 Router Overview and Installation

Connecting Power to Cisco ASR 1002 Router

Figure 6-25 Cisco ASR 1002 Router DC Power Supply Terminal Block Cable Connections

4

OUTPUT

INPUT

FAN

 

FAIL

 

 

OK

 

 

 

OK

 

 

 

 

 

 

 

 

 

 

 

 

 

This unit

 

 

 

 

 

 

 

 

one

might h

ave more

 

power

 

 

 

than

 

supply

 

 

All conne

 

connection.

 

 

ctions must

be removed

to de-energize

 

 

 

 

 

 

 

 

the unit.

 

3

2

 

 

 

 

 

 

 

-

 

 

 

48V/-60V

16A

 

 

 

280290

 

 

1

 

1 Earth ground lead with service loop and

3 Negative lead

tie-wrap

 

 

 

2 Positive lead

 

4 DC power supply Standby switch

Step 3 Using a wire stripper, strip approximately 0.55 inch (14 mm) from the negative, positive, and ground lead.

Step 4 Insert the stripped end of the ground lead all the way into the ground lead receptacle on the DC-input power supply, and tighten the receptacle screw using a 3.5mm flat-blade screwdriver to a torque of 0.5 to 0.6Nm.

Step 5 Insert the stripped end of the positive lead all the way into the positive lead receptacle and tighten the receptacle screw using the same 3.5mm flat-blade screwdriver. Repeat this step for the negative lead.

Note Make sure the entire stripped end of each lead is inserted all the way into its receptacle. If any exposed wire at the stripped end of a lead is visible after inserting the lead into its receptacle, remove the lead from the receptacle, use the wire stripper to cut the stripped end of the lead, and repeat Step 3 through Step 5.

Step 6 After tightening the receptacle screw for the ground, positive, and negative DC-input leads, use a cable tie to secure the three leads to the power supply faceplate, as shown in Figure 6-25. When securing the ground, positive, and negative DC-input leads to the power supply faceplate, leave a small service loop in the ground lead to ensure that the ground lead is the last lead to disconnect from the power supply if a great deal of strain is placed on all three leads as shown in Figure 6-25.

Caution Make certain that the earth ground lead wire has a service loop before you tie wrap the lead wires to prevent the ground from being disconnected.

 

Cisco ASR 1000 Series Aggregation Services Routers Hardware Installation and Initial Configuration Guide

6-34