Chapter 5 Cisco ASR 1004 Router Overview and Installation

Rack-Mounting a Cisco ASR 1004 Router

Rack-Mounting a Cisco ASR 1004 Router

The Cisco ASR 1004 Router can be installed with both front or rear rack-mount brackets.

Note The chassis rack-mounting flanges are secured directly to the chassis before you lift it into the rack.

Verifying Rack Dimensions

Before you install the chassis, measure the space between the vertical mounting flanges (rails) on your equipment rack to verify that the rack conforms to the measurements shown in Figure 5-6.

Step 1 Mark and measure the distance between two holes on the left and right mounting rails.

The distance should measure 18.31 inches ± 0.06 inches (46.5 cm ± 0.15 cm).

Note Measure for pairs of holes near the bottom, middle and top of the equipment rack to ensure that the rack posts are parallel.

Step 2 Measure the space between the inner edges of the left front and right front mounting flanges on the equipment rack.

The space must be at least 17.7 inches (45 cm) to accommodate the chassis which is 17.25 inches (43.8 cm) wide and fits between the mounting posts on the rack.

Figure 5-6 Verifying Equipment Rack Dimensions

Mounting flanges

Minimum usable

aperture 17.7 inches

(45.0 cm)

Hole centerline

to hole centerline

18.31inches ± 0.06 inches (46.5 cm ± 0.15 cm)

28014

Cisco ASR 1000 Series Aggregation Services Routers Hardware Installation and Initial Configuration Guide

 

OL-13208-03