Appendix B Troubleshooting Initial Startup Problems

General Troubleshooting Tips

Troubleshooting the Power Subsystem

Check the following to help isolate a problem with the power system:

Table B-2

Troubleshooting the Power System

 

 

 

 

 

Symptom

 

Possible Cause

Possible Solution

 

 

 

System begins power

System has failed to boot.

There is a power fault in the chassis.

on

 

 

Note that the The system status LEDs are

 

 

 

 

 

 

located on the Cisco ASR 1000 RP1 front

 

 

 

panel. The LEDs stay amber during the

 

 

 

entire IOS boot process and then turn

 

 

 

green when IOS has completely booted.

 

 

 

System does not

AC power cable not fully seated at

Turn the router power switch to the

power on.

 

system or at the wall outlet (power

standby position () and reseat the AC

 

 

source).

power cable at the system or at the wall

 

 

 

outlet (power source).

 

 

 

 

 

 

DC power cable not turned on at the

Turn the router power switch to the

 

 

panel board of the circuit breaker.

standby position () and locate the circuit

 

 

 

breaker on the panel board that services

 

 

 

the DC circuit; switch the circuit breaker

 

 

 

to the on position.

 

 

 

 

 

 

AC internal power cables are not

Turn the router power switch to the

 

 

fully seated from the power supply

standby position () and remove and

 

 

 

reinsert the power supply cable.

 

 

 

System does not

DC internal power cables are not

Check that all ground cables are properly

power on.

 

fully seated on the terminal block.

seated in the terminal block on the DC

 

 

 

power supply.

 

 

 

 

 

 

Power source is faulty.

Turn the power source switch off, connect

 

 

 

the power cable to another power source,

 

 

 

if available, and turn the router power

 

 

 

switch back on.

 

 

 

 

 

 

Faulty power cable.

Turn the router power switch to the

 

 

 

standby position (), (for DC power, also

 

 

 

turn the circuit breaker to the Off position

 

 

 

and tape it to that position), remove the

 

 

 

cable and replace it.

 

 

 

 

 

 

Faulty power supply.

If the system still fails to come up when

 

 

 

the power supply is connected to a

 

 

 

different power source with a new power

 

 

 

cable, the power supply is probably

 

 

 

faulty. Contact a service representative.

 

 

 

 

 

Cisco ASR 1000 Series Aggregation Services Routers Hardware Installation and Initial Configuration Guide

B-16

OL-13208-03

Page 270
Image 270
Cisco Systems ASR 1000 Series manual Troubleshooting the Power Subsystem, Symptom Possible Cause Possible Solution