Chapter 8 Replacing Cisco ASR 1000 Series Routers Field-Replaceable Units

Removing and Replacing a Cisco ASR 1006 Router Power Supply

Figure 8-20 Cisco ASR 1006 Router DC Power Supply Terminal Block Cable Connections

1 2

OFF

-48/-60V 40A

This unit might have more than one power supply connection. All connections must be removed to de-energ

4

3

 

 

 

280024

 

 

 

 

1

Negative lead

3

Protective sleeving around the stud and cable

 

 

 

 

2

Positive lead

4

Earth ground stud and cable

 

 

 

 

Step 6 Locate the power supply ground stud (Figure 8-20). Remove the earth ground (GND) cable from the DC power supply.

Step 7 Loosen and remove the Kepnut screw, washer, and ground lug in that order.

Warning When installing the unit, the ground connection must always be made first and disconnected last.

Step 8 Loosen the four captive screws on the DC power supply.

Note Two power supplies must be installed in the chassis at all times to ensure sufficient cooling. The system fans are inside the power supply units and must spin for cooling. Because all the system fans can be powered by one power supply, the second power supply unit does not have to be powered on, but it must be installed.

Caution If you remove a power supply, the system can run for a maximum of five minutes before the system shuts down. The fans and power elements are independent within the power supply. Therefore, it is not required that the replacement power supply be energized within five minutes. The only requirement is that the power supply be installed in the chassis, which energizes the fans and maintains proper system cooling.

Step 9 Grasping the power supply handles, pull the power supply from the chassis.

Cisco ASR 1000 Series Aggregation Services Routers Hardware Installation and Initial Configuration Guide