ASYD : Assignment of System Data

 

 

SYSTEM

DATA

 

BIT

 

 

SYSTEM

 

CORRESPONDING

 

 

DATA

(DATA)

 

DATA

 

 

DATA

 

 

 

INDEX

00 FF

 

 

SYSTEM DATA CONTENTS

TYPE

 

 

 

 

 

(SYS)

 

(INDEX)

(Hex)

DATA

 

 

 

 

0 511

 

BIT

 

 

 

 

 

0/1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Configuration of CPU (for IPX)

 

 

 

 

 

 

b0

 

0/1 = Single/Dual

 

 

 

 

 

 

 

 

For IPX, assign “0.”

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

b1

 

Not used

 

 

 

 

1

 

b2

 

Trunk Ineffective Hold Detect Processing Program Start

 

 

 

 

 

 

0/1 = Not Required/Required (Always assign “1.”)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

b3

 

Send Forced Off-Hook Supervisory Command

 

 

 

 

 

 

0/1 = Not Required/Required (Always assign “1.”)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

b4

 

Not used

 

 

 

 

 

 

 

 

 

 

58

 

0

 

b5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LP Residual Link Detect (for IPX-UMG system only)

 

 

 

 

 

 

 

 

0 = All LP per a day

 

 

 

 

 

 

 

 

1 = 1 LPG per a day (1LPG consists of four IMGs)

 

 

 

 

 

 

b6

 

Note: As related to the total necessary time of Routine

 

 

 

 

 

 

 

 

Diagnosis, designate the number of LP to be executed

 

 

 

 

 

 

 

 

the LP Residual Link Detect per a day. This data is

 

 

 

 

 

 

 

 

effective when ASYD SYS1 INDEX90 bit3=1 (Residual

1

 

 

 

 

 

 

 

Link Detect is to be executed) is assigned.

 

 

 

 

 

 

 

 

 

 

 

0

 

b7

 

Not used

 

 

 

 

 

 

 

 

 

 

 

 

b0

 

Incoming Call Restriction from TRK during Line Load Control

 

 

 

 

 

 

 

0/1 = Not Required/Required

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LCR – Controlled Alternate PRSC (FRLs) service (urgent mode

 

 

 

 

 

 

 

 

via AUNE)

 

 

 

 

 

 

b1

 

0/1 = Out/In Service

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note: When “1” is assigned, the FRL key on the Attendant

 

 

 

 

 

 

 

 

Console is effective.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b2

 

DID Busy Condition

 

 

59

 

 

 

 

0/1 = No Tone/Busy Tone

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

b3

 

Not used

 

 

 

 

 

 

 

 

 

 

 

 

0

 

b4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

b5

 

Number of Tones sent for Override services

 

 

 

 

 

 

0/1 = 2/3 Tones

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

b6

 

Send Tones for Attendant and Override services

 

 

 

 

 

 

0/1 = Yes/No

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b7

 

Intercom service for Dterm

 

 

 

 

 

 

 

0/1 = Out/In Service

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 