ASYD : Assignment of System Data

 

SYSTEM

 

 

BIT

 

 

 

 

 

SYSTEM

DATA

CORRESPONDING

 

 

 

 

 

DATA

 

 

 

 

 

DATA

(DATA)

 

DATA

 

 

 

 

 

INDEX

 

 

SYSTEM DATA CONTENTS

TYPE

00 - FF

 

 

 

 

(SYS)

(INDEX)

(Hex)

DATA

 

 

 

 

 

 

 

0 - 511

 

BIT

 

 

 

 

 

 

 

0/1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b0

Output Port for SMDR A Apparatus

 

 

 

 

 

 

 

• When b4 = 0 (IOC equipment No. 0)

 

 

 

 

 

 

b1

 

 

 

 

 

 

• b0 = Port 0

b1 = Port 1

b2 = Port 2b3 = Port 3

 

 

 

 

 

b2

 

 

 

 

 

• When b4 = 1 (IOC equipment No. 1)

 

 

 

 

 

 

b3

• b0 = Port 4

b1 = Port 5

b2 = Port 6 b3 = Port 7

 

288

 

 

 

 

• “1” is to be assigned to each bit corresponding to the Port No.

 

 

 

 

b4

 

 

 

 

 

Note 1, Note 2, Note 3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

b5

Expanded SMDR for “A” apparatus.

 

 

 

 

0

 

b6

Not used

 

 

 

 

 

 

 

0

 

b7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b0

Fault detection timer of SMDR A

 

 

 

 

 

 

 

 

b1

Value for the first digit (min):

 

Timer value ranges

 

 

 

 

 

b2

(0~9) Hex

 

 

 

from 1 to 99 min-

 

 

 

 

 

 

A~F Hex: Not used

 

 

utes.

 

 

 

 

 

b3

 

 

1

289

 

 

 

 

 

 

00 Hex: Without

 

 

 

b4

 

 

 

 

 

 

 

 

Fault detection timer of SMDR A

 

 

fault detection

 

 

 

 

 

b5

Value for the second digit (min):

 

Normally, Assign 00

 

 

 

 

 

 

(0~9) Hex

 

 

Hex.

 

 

 

 

 

b6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A~F Hex: Not used

 

 

 

 

 

 

 

 

b7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b0

Output Port for SMDR B Apparatus

 

 

 

 

 

 

 

• When b4 = 0 (IOC equipment No. 0)

 

 

 

 

 

 

b1

 

 

 

 

 

 

• b0 = Port 0

b1 = Port 1

b2 = Port 2 b3 = Port 3

 

 

 

 

 

b2

 

 

 

 

 

• When b4 = 1 (IOC equipment No. 1)

 

 

 

 

 

 

b3

• b0 = Port 4

b1 = Port 5

b2 = Port 6b3 = Port 7

 

290

 

 

 

 

• “1” is to be assigned to each bit corresponding to the Port No.

 

 

 

 

b4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note 1, Note 2, Note 3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b5

Expanded SMDR for “B” apparatus.

 

 

 

 

 

 

b6

Not used

 

 

 

 

 

 

 

 

 

b7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note 1: Among the SMDR equipment that has the same IOC equipment number, double assignment of the port is rejected.

Note 2: The ports to be designated by SYS-1, INDEX 288, 290, 292, and 294 are limited to those designated as SMDR by AIOC.

Note 3: This data is assigned at the node to which SMDR with IOC interface is connected. In case SMDR is not connected to the node, this data setting is fixed to “0”.