NEC NDA-24298 manual To 30 min, ASYDN, SYS1, Index

Models: NDA-24298

1 1020
Download 1020 pages 51.64 Kb
Page 950
Image 950

ASYDN : Assignment of System Data in Network Data Memory

SYSTEM

SYSTEM

DATA

BIT

 

 

 

DATA

CORRESPONDING

 

DATA

(DATA)

 

INDEX

DATA

 

SYSTEM DATA CONTENTS

(MDATA)

TYPE

00 – FF

 

(INDEX)

 

 

 

 

(SYS)

(Hex)

DATA 0/1

BIT

 

0 – 1535

 

 

 

 

 

 

 

 

 

 

 

 

80

00

 

 

Not used

 

~

~

 

 

~

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

90

00

 

 

 

Not used

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

b0

 

Not used

 

 

 

 

 

 

0

b1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b2

 

Grades of System Message that can be registered:

 

 

 

 

 

 

b3

 

b2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

0

=

Register All System Message Data

 

 

 

 

 

0

1

=

Register System Message Data higher than grade

 

 

 

 

b3

 

 

 

 

 

1 (SUP, MN, MJ)

 

 

91

 

 

1

0

=

Register System Message Data higher than grade

 

 

 

 

 

 

 

 

 

 

 

 

 

2 (MN, MJ)

 

 

 

 

 

 

 

1

1

=

Register System Message Data higher than grade

 

 

 

 

 

 

 

 

 

 

3 (MJ)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

b4

 

 

 

 

 

 

 

 

 

 

 

0

b5

 

Not used

 

 

 

 

 

 

0

b6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

b7

 

 

 

 

 

 

 

 

92~158

00

 

 

 

Not used

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

OG Trunk Queuing Automatic

The duration before the OG

 

 

 

 

 

 

Cancel Timer (for Fusion Ser-

Queuing memory becomes

 

 

 

 

 

 

vice):

 

 

cleared if no trunks become

 

 

 

 

b0~b6

 

Miscellaneous Timer Counter

idle. Timer Value Setting is

 

 

 

 

 

 

(MTC) is to be assigned a val-

MTC 30 sec.

 

 

 

 

 

 

ue from 0 Hex to 7F Hex

 

 

 

 

 

 

 

(0~127).

 

Note: When this data is

159

 

 

 

 

 

 

 

 

 

00 Hex, default

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

data is

 

 

 

 

 

 

 

 

 

 

 

automatically set

 

 

 

 

b7

 

Not used

 

to 30 min.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

This timer is effective when

 

 

 

 

 

 

 

 

 

 

 

ASYDN, SYS1, INDEX 68,

 

 

 

 

 

 

 

 

 

 

 

b3 = “1.”

160

00

 

 

 

Not used

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b0~b5

 

Not used

 

 

 

 

 

 

 

 

 

Timing Start using “#” code

 

 

161

 

 

b6

 

0/1 = Ineffective/Effective

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Timing Start using “*”

 

 

 

 

 

 

b7

 

0/1 = Ineffective/Effective

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CHAPTER 4

 

 

 

 

 

NDA-24298

 

 

Page 916

 

 

 

 

 

 

 

 

 

 

 

Issue 1

 

 

 

 

 

 

 

 

 

 

 

Page 950
Image 950
NEC NDA-24298 manual To 30 min, ASYDN, SYS1, Index