NEC NDA-24298 manual 294

Models: NDA-24298

1 1020
Download 1020 pages 51.64 Kb
Page 185
Image 185

ASYD : Assignment of System Data

 

SYSTEM

 

 

BIT

 

 

 

 

 

 

 

SYSTEM

DATA

CORRESPONDING

 

 

 

 

 

 

 

DATA

 

 

 

 

 

 

 

DATA

(DATA)

 

DATA

 

 

 

 

 

 

 

INDEX

 

 

 

SYSTEM DATA CONTENTS

 

TYPE

00 - FF

 

 

 

 

 

 

(SYS)

(INDEX)

(Hex)

DATA

 

 

 

 

 

 

 

 

 

0 - 511

 

BIT

 

 

 

 

 

 

 

 

 

0/1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b0

 

Output Port for SMDR D Apparatus

 

 

 

 

 

 

 

 

• When b4 = 0 (IOC equipment No. 0)

 

 

 

 

 

 

b1

 

 

 

 

 

 

b0 = Port 0

b1 = Port 1

b2 = Port 2

b3 = Port 3

 

 

 

 

 

b2

 

 

 

 

 

• When b4 = 1 (IOC equipment No. 1)

 

 

 

 

 

 

b3

b0 = Port 4

b1 = Port 5

b2 = Port 6

b3 = Port 7

 

 

 

 

 

 

 

“1” is to be assigned to each bit corresponding to the Port No.

 

 

 

 

 

 

 

 

 

 

 

 

 

Note 1: Among the SMDR equipment that has the same IOC

 

 

 

 

 

 

 

equipment number, double assignment of port is

 

 

 

 

 

 

 

rejected.

 

 

 

 

 

 

294

 

 

 

b4

Note 2: The ports to be designated by SYS-1, INDEX 288, 290,

 

 

 

 

 

 

292, and 294 are limited to those designated as SMDR

 

 

 

 

 

 

 

by AIOC.

 

 

 

 

 

 

 

 

 

 

Note 3: This data is assigned at the node to which SMDR with

 

 

 

 

 

 

 

IOC interface is connected. In case SMDR is not

 

 

 

 

 

 

 

connected to the node, this data setting is fixed to “0”.

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

b5

 

Expanded SMDR for “D” apparatus.

 

 

 

 

 

 

b6

 

Not used

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b0

 

Fault detection timer of SMDR D

 

 

 

 

 

 

 

 

 

b1

 

Value for the first digit (min):

 

Timer value ranges

 

 

 

 

 

 

 

(0~9) Hex

 

 

 

from 1 to 99 min-

 

 

 

 

 

b2

 

 

 

 

 

 

 

 

 

 

 

A~F Hex: Not used

 

 

utes.

 

 

 

 

 

b3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

295

 

 

 

 

 

 

 

00 Hex: Without

 

 

 

 

b4

 

Fault detection timer of SMDR D

 

 

 

 

 

 

 

 

 

fault detection

 

 

 

 

 

b5

 

Value for the second digit (min):

 

 

Normally, Assign 00

 

 

 

 

 

b6

 

(0~9) Hex

 

 

 

Hex.

 

 

 

 

 

 

 

 

A~F Hex: Not used

 

 

 

 

 

 

 

 

 

b7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

296

00

 

 

 

 

Not used

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

~

~

 

 

 

~

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

303

00

 

 

 

 

Not used

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NDA-24298CHAPTER 4

Page 151

Issue 1

Page 185
Image 185
NEC NDA-24298 manual 294