ACMO : Assignment of Clocked Manual Override

ACMO: Assignment of Clocked Manual Override

1.General

This command assigns the Clocked Manual Override data, which is used for changing routes during a specific day and specific time period, such as a holiday (Month/Day/Hour/Minute).

2.Precautions

1.The BLOCK parameter is a data index (0-7). A maximum of eight kinds of Clocked Manual Override Data can be assigned.

2.The PTN parameter corresponds to the TDPTN parameter assigned by the AOPR/ASDC command.

3.The Clocked Manual Override data assigned by ACMO command has priority over the Time Pattern data assigned by the ATCP command.

4.Time is designated in Military Time. 24 cannot be used as Hour designation.

5.A single set of PTN (Pattern Number) and START/END date and time is to be assigned to a BLOCK Number. Also the same PTN can be specified to multiple BLOCK Numbers.

6.“PTN = 0” is also used in default setting (in unspecified time period). Thus the assignment “PTN = 0” means nothing in this command.

3.Data Entry Instructions

BLOCK

Enter a block number for a Clocked Manual Override data

DATE

Month/Day

ex.) 09/20 = September 20

BLOCK NUMBER

PATTERN NUMBER

 

START

 

 

 

END

 

 

REMARKS

(BLOCK)

(PTN)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0-7

0-7

DATE

TIME

DATE

TIME

 

 

 

 

 

 

 

 

 

 

 

 

 

09

20

17

00

09

21

09

00

 

 

 

 

 

 

 

 

 

 

 

 

PTN

Pattern number (0-7) assigned by the AOPR/AOPRL/ASDC command.

TIME

Hour/Minute