NEC NDA-24298 manual Application Code Code, Ebcd, Profile Number Prfn HOT Line Terminal HL

Models: NDA-24298

1 1020
Download 1020 pages 51.64 Kb
Page 543
Image 543

ADA2 : Assignment of DTE Attribute Data 2

TENANT NUMBER (TN)

CDN

 

 

 

 

 

STATION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NUMBER

 

 

FUNCTION

 

(STN)

 

 

 

 

 

APPLICATION CODE (CODE)

 

 

0

=

No Character

 

 

 

 

1

=

ASCII (7-bit) Even Parity

 

 

2

=

ASCII (7-bit) Odd Parity

 

 

3

=

ASCII (7-bit) Parity is “0”

 

 

4

=

ASCII (7-bit) Parity is “1”

 

10

5

=

JIS (7-bit) Even Parity

 

6

=

JIS (7-bit) Odd Parity

 

 

 

 

7

=

JIS (8-bit)

 

 

 

 

8

=

EBCDIC (8-bit)

 

 

 

9

=

IA#5 (7-bit)

 

 

 

 

10 =

ITA#2 (5-bit)

 

 

 

 

11 =

EBCD

 

 

 

 

12-15=Not used

 

 

 

 

 

 

11

PROFILE NUMBER (PRFN)

 

0-63

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12

HOT LINE TERMINAL (HL)

 

0

=

No Hotline

1

= Hotline

 

 

 

 

 

 

 

HOT LINE ORIGINATE (HTL)

 

13 0

=

DTR (ER) Signal On

 

 

1

=

Normal Origination

 

 

 

 

 

 

 

KIND OF RA(RA)

 

 

 

 

0

=

PROTIMS

 

 

 

 

1

=

PROTIMS

 

 

 

 

2

=

DMI Mode 2

 

 

 

14

3

=

PROTIMS

 

 

 

4

=

V. 110

5

= V. 120

 

 

 

 

6

=

X. 30

7-15= Not used

 

Note: In the case of PROTIMS, assign “0.”