ATDPL : Assignment of Toll Code Restriction Data for LDM

If data is set as follows, a toll call can be restricted by developing NPA - Nxx.

At Toll Code Restriction Data for LDM (ATDPL) DC = 9-1, TDI = 2, NND = 6 (NPA - Nxx)

At Area & Office Code Data (AARPL) DC = NAP - Nxx (6 digits)

4.Data can be entered on a Day/Night basis, if specified in ASYD command, SYS 1, INDEX 75, Bit 3=1.

3.Data Entry Instructions

Outgoing Connection

DAY/NIGHT

D = Day Mode

N = Night Mode

TDI

0 = Connection is Restricted

1 = Connection is Allowed

2 = 3/6 Digit Toll Restriction

3 = C.O. Operator Call (9+0)

NND

This parameter is available only when TDI=2

DAY/NIGHT

MODE

(DAY/NIGHT)

ROUTE

OUTGOING

RESTRICTION

LOGICAL ROUTE

NUMBER

NUMBER

(RSC) 0-15

(OGLGRT) 1-899

 

 

DESTINATION (AREA) CODE

(DC)

MAX. 11 DIGITS

RESTRICTION

NECESSARY

DATA

DIGIT

(TDI)

(NND)

0-3

1-12

 

 

Refer to the ARSCN command.

When assigning DC, the digits including the access code must be assigned.