AUNEL : Assignment of Uniform Numbering for LDM

AUNEL: Assignment of Uniform Numbering for LDM

1.General

This command assigns the data for an inter-network call termination.

2.Precautions

This command is available for both ACIS and CCIS. The call termination from CCIS requiring the office code skip needs this data.

Example: When the network numberings are as follows, example office data is listed in the table.

Node A 8 - 26 - xxxxx

Node B 8 - 10 - xxxxx

 

Node A

 

 

ARTD

RT = dummy, AC = 1

 

 

ASPAL/N

ACC = 8, SRV = LCR, RT = dummy

 

 

AUNEL

RT = dummy, NPC = 826, SKIP = 3

 

 

AMND

DC = 826, MND = 8

 

 

ARRCN

Allow the connection between ICRT

 

(Voice route in the case of CCIS) and

 

OGRT (Dummy route).

 

 

 

Node B

 

 

ARTD

RT = dummy, AC = 1

 

 

ASPAL/N

ACC = 8, SRV = LCR, RT = dummy

 

 

AUNEL

RT = dummy, NPC = 810, SKIP = 3

 

 

AMND

DC = 810, MND = 8

 

 

ARRCN

Allow the connection between ICRT

 

(Voice route in the case of CCIS) and

 

OGRT (Dummy route).

 

 

1.The applicable tenant number (TN) range is designated by the ASYD command, SYS1, INDEX8. If data in this command is common for all tenants (ASYDL command, SYS1, INDEX800, bit4=1), assign TN parameter as data “1” for all tenants.

2.Assign the dummy route number in the LGRT parameter.

3.The data assigned in the NPC should include its access code, and should be different from the NPC assigned by the AFRSL command.

4.The PNL parameter (which is intermediate data to assign the AADCL command) appears when ASYD command SYS1, INDEX42, bit4=1.

5.Enter the PNL data if additional digit (DC) is required. A maximum of 24 digits of DC is set by the AADCL command. Enter the PNL with a range from 1 to 127. If additional digit is not required, data “0” is to be set to the PNL parameter.