1.General

This command is used to readout/assign/delete the controlling data of Trunk Group Busy Lamp which is accommodated on the Attendant Console. This data is written in Local Data Memory (LDM).

2.Precautions

1.The number of Attendant Consoles should be assigned by the ASYD command, SYS1, INDEX9.

2.The Trunk Group Busy Lamp lit when the trunk routes specified by the LGRT parameter of this command are engaged.

3.The number of Trunk Group Busy Lamps to be applied (capable TGN data range) is assigned by the ASYD command, SYS1, INDEX15, bit0-3.

3.Data Entry Instructions

ATN

Enter the Attendant Console Number assigned by the ATRK command.

DATA

0 = Not registration 1= Registration

ATTTENDANT

TRUNK GROUP

LOGICAL ROUTE

 

 

BUSY LAMP

LGRT DATA

 

NUMBER

NUMBER

REMARKS

NUMBER

(DATA)

(ATN)

(LGRT)

(TGN)

0/1

 

1-30

1-899

 

1-10

 

 

 

 

 

 

 

TGN

 

LGRT

 

Enter the Trunk Group Busy Lamp

Enter the logical route number

Number on the Attendant Console.

composed the Trunk Group (TGN).