AIOC : Assignment of IOC Port Data

TERMINAL=7 (PMS) / 8 (Hotel Printer)

(PROTOCOL)

(SPEED)

(PARITY BIT)

(STOP BIT)

(SYNC)

(CHARACTER

(SYNC CHAR-

(BUSY SIGNAL)

0-2

0-6

0-3

0-3

0/1

BIT) 0/1

ACTER) 0/1

0/1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PROTOCOL

0=Free Wheeling 1=BSC Pooling 2=BSC Contention 3=Level 2A 4=Level 2B

PARITY BIT

0=Non Parity

1=Odd Parity

2=Even Parity

3=Non Parity

SPEED

0=Default(4800bps)

1=300bps2=600bps

3=1200bps 4=2400bps

5=4800bps 6=9600bps

SYNC

0=ST1

1=ST2

STOP BIT

0=2bits

1=1bit

2=1+1/2bits

3=2bits

SYNC CHARACTER 0=Bi-sync

1=Mono-sync

 

CHARACTER BIT

 

 

 

BUSY SIGNAL

 

 

 

 

0=8bits

 

 

 

0=(+)

1=(-)

 

 

1=7bits

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(PB SIGNAL)

(ENH)

0/1

0/1

 

 

 

 

ENH

(Extended block parameter)

0=Invalid Note

1=Valid (Continue to following attribution data assignment.) Note: Standard data is "0".

PB SIGNAL

0=No PB signal

1=PB signal is required

Following optional parameters appear when ENH (Extended block parameter) = 1.

(CLASS)

(PM)

(CN)

(FL)

(ET)

(KJ)

(WR)

(DR)

0-3

0/1

0-3

0/1

0/1

0/1

 

0/1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CLASS

0=-CR/LF 1=-CR 2=STX-ETX 3=STX-ETX/BCC

CN

(Continuous

Transmission)

0=Invalid

1=Valid

ET

(EOT on reset)

0=Invalid

1=Valid

WR

(Transmission method)

0 Fixed. (RS ON always)

PM

(Priority Point specification)

0=First Priority Point 1=Second Priority Point

FL

(Reception

buffer shortage)

0=NAK

1=WABT

KJ

(Kanji Character code)

0=Invalid

1=Valid

DR

(DR signal disregard)

0=Invalid

1=Valid