NEC NDA-24298 manual LP08 #0 is mounted on PBI40 Module for IPX-UMG system

Models: NDA-24298

1 1020
Download 1020 pages 51.64 Kb
Page 171
Image 171

ASYD : Assignment of System Data

SYSTEM

SYSTEM

DATA

 

BIT

 

CORRESPONDING

 

DATA

 

DATA

(DATA)

 

DATA

 

INDEX

 

SYSTEM DATA CONTENTS

TYPE

00 - FF

 

 

 

(INDEX)

 

 

 

 

(SYS)

(Hex)

DATA

 

BIT

 

0 - 511

 

 

 

 

0/1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b0

LP08 #0 is mounted on PBI40 Module for IPX-UMG system

 

 

 

 

 

b1

LP08 #1 is mounted on PBI40 Module for IPX-UMG system

 

 

 

0

 

b2

Not used

 

200

 

0

 

b3

 

 

 

 

 

 

 

 

b4

LP10 #0 is mounted on PBI44 Module for IPX-UMG system

 

 

 

 

 

 

 

 

 

 

b5

LP10 #1 is mounted on PBI44 Module for IPX-UMG system

 

 

 

0

 

b6

Not used

 

 

 

0

 

b7

 

 

 

 

 

 

 

 

 

 

b0

LP12 #0 is mounted on PBI48 Module for IPX-UMG system

 

 

 

 

 

b1

LP12 #1 is mounted on PBI48 Module for IPX-UMG system

 

 

 

0

 

b2

Not used

 

201

 

0

 

b3

 

 

 

 

 

 

 

 

b4

LP14 #0 is mounted on PBI4C Module for IPX-UMG system

 

 

 

 

 

 

 

 

 

 

b5

LP14 #1 is mounted on PBI4C Module for IPX-UMG system

 

 

 

0

 

b6

Not used

 

 

 

0

 

b7

 

 

 

 

 

 

 

 

 

 

b0

LP16 #0 is mounted on PBI50 Module for IPX-UMG system

 

 

 

 

 

b1

LP16 #1 is mounted on PBI50 Module for IPX-UMG system

 

 

 

0

 

b2

Not used

1

202

 

0

 

b3

 

 

 

 

 

 

b4

LP18 #0 is mounted on PBI54 Module for IPX-UMG system

 

 

 

 

 

 

 

 

 

 

b5

LP18 #1 is mounted on PBI54 Module for IPX-UMG system

 

 

 

0

 

b6

Not used

 

 

 

0

 

b7

 

 

 

 

 

 

 

 

 

 

b0

LP20 #0 is mounted on PBI58 Module for IPX-UMG system

 

 

 

 

 

b1

LP20 #1 is mounted on PBI58 Module for IPX-UMG system

 

 

 

0

 

b2

Not used

 

203

 

0

 

b3

 

 

 

 

 

 

 

 

b4

LP22 #0 is mounted on PBI5C Module for IPX-UMG system

 

 

 

 

 

 

 

 

 

 

b5

LP22 #1 is mounted on PBI5C Module for IPX-UMG system

 

 

 

0

 

b6

Not used

 

 

 

0

 

b7

 

 

 

 

 

 

 

 

 

 

b0

LP24 #0 is mounted on PBI60 Module for IPX-UMG system

 

 

 

 

 

b1

LP24 #1 is mounted on PBI60 Module for IPX-UMG system

 

 

 

0

 

b2

Not used

 

204

 

0

 

b3

 

 

 

 

 

 

 

 

b4

LP26 #0 is mounted on PBI64 Module for IPX-UMG system

 

 

 

 

 

 

 

 

 

 

b5

LP26 #1 is mounted on PBI64 Module for IPX-UMG system

 

 

 

0

 

b6

Not used

 

 

 

0

 

b7

 

 

 

 

 

NDA-24298CHAPTER 4

Page 137

Issue 1

Page 171
Image 171
NEC NDA-24298 manual LP08 #0 is mounted on PBI40 Module for IPX-UMG system