AANI : Assignment of ANI Data

AANI: Assignment of ANI Data

1.General

This command assigns Automatic Number Identification (ANI) data sent per tenant by the request from opposite office.

2.Precautions

1.Before using this command, ASYD SYS1 INDEX 125 b4 - b7 (Type of MFC Signaling System) should be assigned.

2.When ASYD command, SYS 2 INDEX 15, b2 = 1, the following number is sent as ANI data.

(a)Calling party is a station:

Calling party’s station number is sent.

(b)Calling party is an Attendant or tandem connection: LDN assigned in this command is sent.

If b2 = 0, LDN assigned in this command is sent.

3.The ANI parameter of ARTD command should be assigned prior to this command.

4.The applicable Tenant Number (TN) range is designated by the ASYD command, SYS 1, INDEX 8.

3.Data Entry Instructions

TS

This paramenter is not used. (For China only) Press SPACE key and Enter key in order to skip this parameter.

LS

If no LS (Local Number) of ANI is required, enter "*" or "#" in this parameter.

The LS is not included in ANI.

TENANT

CALL NUMBER OF TOLL CALL NUMBER OF LOCAL

LISTED DIRECTORY

NUMBER

(TS)

(LS)

NUMBER (LDN)

(TN)

MAXIMUM 8 DIGITS

MAXIMUM 8 DIGITS

MAXIMUM 8 DIGITS