Image 155

ASYD : Assignment of System Data

 

SYSTEM

 

 

BIT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SYSTEM

DATA

CORRESPONDING

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DATA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DATA

(DATA)

 

DATA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INDEX

 

 

 

 

 

 

 

 

SYSTEM DATA CONTENTS

TYPE

00 - FF

 

 

 

 

 

 

 

 

 

 

(SYS)

(INDEX)

(Hex)

DATA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0 - 511

 

BIT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0/1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b0

Trunk Soft Hold Timer A:

 

 

 

 

 

 

 

 

 

 

 

b1

Miscellaneous Timer Counter (MTC) is to

Timer Value Setting

 

 

 

 

 

b2

be assigned a value from 0 Hex to F Hex

 

 

 

 

 

is MTC TC sec.

 

 

 

 

 

 

(0-15).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note: When this

 

 

 

 

 

b4

 

Timer Class (TC) is to be assigned one of

 

 

 

 

 

 

data is 00

 

 

 

 

 

 

 

the following values:

 

 

 

 

 

 

 

 

 

 

 

 

b5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Hex, default

 

156

 

 

 

 

b6

 

b5

 

b4

 

 

b6

b5

b4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

data is

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

automatically

 

 

 

 

 

 

0

0

0

=

1

 

0

0

=

 

 

 

 

 

 

 

set to 30 sec.

 

 

 

 

 

b6

 

0 0 1 = –

1 0 1 = –

 

 

 

 

 

 

 

0

1

0

=

1

 

1

0

=

 

 

 

 

 

 

 

0

1

1

=

2 sec.

1

 

1

1

=

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

0

 

b7

 

Not used

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b0

Trunk Soft Hold Timer B:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b1

Miscellaneous Timer Counter (MTC) is to

 

 

 

 

 

 

b2

be assigned a value from 0 Hex to F Hex

 

 

 

 

 

 

 

(0-15).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b4

 

Timer Class (TC) is to be assigned one of

 

 

 

 

 

 

 

 

the following values:

 

 

 

 

 

 

 

Timer Value Setting

 

 

 

 

 

b5

 

 

 

 

 

 

 

 

157

 

 

 

 

 

b6

 

b5

 

b4

 

 

b6

 

b5

b4

 

 

is MTC TC sec.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note

 

 

 

 

 

 

 

0

 

0

 

0

=

1

 

0

0

=

 

 

 

 

 

 

 

 

 

 

 

 

 

b6

 

0 0 1 = –

1 0 1 = –

 

 

 

 

 

 

 

0

1

0

=

1

 

1

0

=

 

 

 

 

 

 

 

0

1

1

=

2 sec.

1

 

1

1

=

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

b7

 

Not used

 

 

 

 

 

 

 

 

 

 

Note: When this data is 00 Hex, default data is automatically set to 18 sec. If Answer Signal is not received from destination office in C.O./Tie Line originating calls via Sender (ARTD ANS = 0 is set), Answer Signal is sent when this timer expires. (For tandem connection, assign the data at SYS1, INDEX 243.)