ASYDL : Assignment of System Data into Local DM (LDM)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SYSTEM

 

 

BIT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SYSTEM

DATA

CORRESPONDING

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DATA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DATA

(DATA)

 

DATA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INDEX

 

 

 

 

 

 

 

 

 

 

SYSTEM DATA CONTENTS

 

TYPE

00 - FF

 

 

 

 

 

 

 

 

 

 

 

 

 

(SYS)

(INDEX)

(Hex)

DATA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

512 - 1535

 

BIT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0/1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Centralized Billing-Fusion output text format of

 

 

 

 

 

b0

 

 

SMDR C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0/1 = IMS (ICS) format/IPX format

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

580

 

 

 

b1 ~ b3

 

Not used

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b4

 

 

0/1 = SMDR C Apparatus with LAN interface is not

 

 

 

 

 

 

 

 

 

 

 

used/used. Note

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b5 ~ b7

 

Not used

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Centralized Billing-Fusion output text format of

 

 

 

 

 

b0

 

 

SMDR D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0/1 = ICS format/IPX format

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

581

 

 

 

b1 ~ b3

 

Not used

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b4

 

0/1 =

SMDR D Apparatus with LAN interface is

 

 

 

 

 

 

 

 

 

 

 

not used/used. Note

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b5 ~ b7

 

Not used

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The number of the node to be polled in a polling

 

 

 

 

 

 

 

 

0000 = 1

0001 = 1

 

0010 = 2

0011 = 3

1

 

 

 

 

b0 ~ b3

0100 = 4

0101 = 5

 

0110 = 6

0111 = 7

 

582

 

 

 

1000 = 8

 

~

 

 

 

1111 = 8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note 1: For numbers more than 8, assign the data

 

 

 

 

 

 

 

 

 

 

 

 

 

 

value as 8.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b4 ~ b7

 

Not used

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The timing for transmitting the billing data of SMDR-

 

 

 

 

 

 

 

 

 

Netfusing from the node that accommodates the

 

 

 

 

 

 

 

 

 

outgoing trunk to the node that accommodates the

 

 

 

 

 

 

 

 

 

called station.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b

b

2

 

b2 b1 b0

 

 

b2 b1 b0

 

 

 

 

 

 

 

 

0 ~

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

583

 

 

 

 

 

 

0

0

 

0 =

8 sec.

1

 

0

0

 

=

8 sec.

 

 

 

 

 

 

 

 

0

0

 

1 =

2 sec.

1

 

0

1

 

=

10 sec.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

1

 

0 =

4 sec.

1

 

1

0

 

=

12 sec.

 

 

 

 

 

 

 

 

 

0

1

 

1 =

6 sec.

1

 

1

1

 

=

14 sec.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b3 ~ b6

 

Not used

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The timing for transmitting the polled billing data

 

 

 

 

 

b7

 

 

assigned at b0 ~ b2 is

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0= In Service

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note: Assign “1” at the node to which SMDR with LAN interface is connected. If not connected, this data setting is fixed to “0”.