NEC NDA-24298 manual Ashu Assignment of Station Hunting Group-UCD

Models: NDA-24298

1 1020
Download 1020 pages 51.64 Kb
Page 706
Image 706

ASHU : Assignment of Station Hunting Group-UCD

ASHU: Assignment of Station Hunting Group-UCD

1.General

This command assigns the data related to the Uniform Call Distribution (UCD) service feature.

2.Precautions

1.This command is also used to modify and delete the UCD service related data.

2.The maximum number of stations within a UCD group is 100.

3.The UCD pilot station (controlling station) is assigned at the STN parameter.

4.Press ESC to skip forward to the WRT? text box when all the desired stations have been entered.

5.Assign the AUAD command if the Delay Announcement-UCD service feature is required.

6.Assign the AUCD command if the following peripheral thresholds are required:

(a)The number of calls in UCD queuing that are used for the UCD Peg Count.

(b)The threshold causes the UCD Call Waiting Lamp located on a Dterm to flash.

(c)Denies the MCI call result text if the call terminated to the UCD group.

7.Assign AUOG command if the Overflow-UCD service feature is required.

8.When assigning the AUAD/AUCD/AUOG commands, the Tenant Number (TN) and the UCD Pilot station (controlling station) number (STN) assigned in this command are used to specify the UCD group.

9.The applicable Tenant Number (TN) range is designated by the ASYD command, SYS 1, INDEX 8.

CHAPTER 4

NDA-24298

Page 672

Issue 1

Page 706
Image 706
NEC NDA-24298 manual Ashu Assignment of Station Hunting Group-UCD