ASHC : Assignment of Station Hunting Group - Circular

ASHC: Assignment of Station Hunting Group - Circular

1.General

This command assigns the data related to the Station Hunting - Circular service feature.

2.Precautions

1.This command is also used to modify and delete the Station Hunting - Circular service feature related data.

2.The maximum number of member stations within a Hunting Group is 100.

3.When assigning the Circular Hunting member station data, the data entered in the STN text box must be reentered as CNT 1 text box.

Example: When the station numbers 300, 301, and 302 are the members of the Station Hunting - Circular group, assign the data as follows:

STN = 300

CNT 1 = 300

CNT 2 = 301

CNT 3 = 302

4.The applicable Tenant Number (TN) range is designated by the ASYD command, SYS 1, INDEX 8.

5.Press ESC to skip forward to the SECRETARY parameter when all the desired member stations have been entered.

6.Enter space (blank) in the SECRETARY parameter if a secretary station is not required.