NEC NDA-24298 When, Index 87, Index Are, Assigned data, Hex, Diagnosis, Program, Not executed

Models: NDA-24298

1 1020
Download 1020 pages 51.64 Kb
Page 131
Image 131

ASYD : Assignment of System Data

 

SYSTEM

 

BIT

 

 

 

 

 

 

 

SYSTEM

DATA

CORRESPONDING

 

 

 

 

 

 

DATA

 

 

 

 

 

 

DATA

(DATA)

DATA

 

 

 

 

 

 

 

INDEX

 

 

SYSTEM DATA CONTENTS

 

 

 

TYPE

00 FF

 

 

 

 

 

 

 

(SYS)

(INDEX)

(Hex)

DATA

 

 

 

 

 

 

 

 

0 511

 

BIT

 

 

 

 

 

 

 

 

0/1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Hour data is assigned using a decimal

 

 

 

 

 

 

 

 

 

 

number (Military Time)

 

 

 

 

 

 

 

 

 

 

Example:

2:00 a.m. –

Routine Diagnosis

 

 

 

 

 

 

 

 

This data is

 

 

87

 

 

 

 

 

Program Start Time

 

 

 

 

 

 

entered as 02.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Example:

2:30 p.m. –

 

 

 

 

 

 

 

 

 

 

 

This data is

Note:

When

 

both

 

 

 

 

 

 

 

 

Index 87 and

 

 

 

 

 

 

 

entered as 14.

 

 

 

 

 

 

 

 

 

Index

88

are

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Minute data is assigned using a deci-

 

 

 

 

 

 

 

 

assigned data

 

 

 

 

 

 

mal number (Military Time)

 

 

 

 

 

 

 

 

“FF”

Hex,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Example:

2:00 a.m. –

 

the

Routine

 

88

 

 

 

 

 

This data is

 

Diagnosis

 

 

 

 

 

 

 

Program

is

 

 

 

 

 

 

entered as 00.

 

 

 

 

 

 

 

 

 

not executed.

 

 

 

 

 

 

Example:

2:30 p.m. –

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

This data is

 

 

 

 

 

 

 

 

 

 

 

entered as 30.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

0

 

b0

Main Memory Check (Generic Program Memory)

 

 

 

 

 

0/1 = No/Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b1

DM Check (DM = Data Memory)

 

 

 

 

 

 

 

 

 

0/1 = No/Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b2

TSW Active/Standby Changeover for Dual Systems

 

 

 

 

 

 

 

0/1 = No/Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(For 1-IMG, 4-IMG, IPX-U system)

 

 

 

 

 

 

 

 

 

 

CPU Active/Standby Changeover for Dual Systems

 

 

 

 

 

 

 

b3

0/1 = No/Yes

 

 

 

 

 

89

 

 

 

(For IPX-UMG system)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SP ACT/STBY Changeover

 

 

 

 

 

 

 

 

 

 

0/1 = No/Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b4

Trunk Ineffective Hold Detect

 

 

 

 

 

 

 

 

 

0/1 = No/Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b5

Trunk Ineffective Hold Release

 

 

 

 

 

 

 

 

 

0/1 = No/Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b6

Call Forwarding Memory Clear

 

 

 

 

 

 

 

 

 

0/1 = No/Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b7

Not used

 

 

 

 

 

NDA-24298CHAPTER 4

Page 97

Issue 1

Page 131
Image 131
NEC NDA-24298 manual When, Index 87, Index Are, Assigned data, Hex, Diagnosis, Program, Not executed