NEC NDA-24298 manual Apcr Assignment of Primary Call Restriction Data, Pdc

Models: NDA-24298

1 1020
Download 1020 pages 51.64 Kb
Page 424
Image 424

APCR : Assignment of Primary Call Restriction Data

APCR: Assignment of Primary Call Restriction Data

1.General

This command assigns the restricted area code for LCR outgoing call.

2.Precautions

1.The restriction check by this command is to be executed prior to the ARSC/ATDP/AARP commands.

2.The restricted area code assigned in the PDC parameter can be numbers (0 - 9, * and #), the mask code “X” which represents all kind of numbers (0 - 9, * and #), or “P” for a pause.

3.The applicable tenant number (TN) range is designated by the ASYD command, SYS1, INDEX8. If data for this command is common for all tenants (ASYD command, SYS1, INDEX94, bit2=1), assign the TN parameter as data “1” for all tenants.

3. Data Entry Instructions

BLOCK

Unique Block Number should be assigned.

PDC

PDC should include the Access Code.

TENANT

BLOCK

PRIMARY CALL

 

 

 

 

 

 

 

 

 

NUMBER

NUMBER

DIGIT CODE

 

ROUTE RESTRICTION CLASS (RSC) 0-15

(TN)

(BLOCK)

(PDC)

 

 

 

 

 

 

 

 

 

 

0-49

MAX. 24 DIGITS

1

2

3

4

5

6

7

8

9 10 11 12 13 14 15

 

 

0

RES

RESTRICTION DATA (RES) is assigned in the squares where RSC and PDC cross. When unassigned allowed Status.

0 = Restricted

1 = Connection is allowed

CHAPTER 4

NDA-24298

Page 390

Issue 1

Page 424
Image 424