ALRNN : Assignment of Logical Route and Route Class Data for NDM

LOGICAL ROUTE (LGRT) 1-899

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FUSION POINT CODE (FPC) 1-253

 

 

 

 

 

 

 

 

 

REMARKS

 

 

 

 

 

 

 

 

 

 

 

 

 

ROUTE NUMBER (RT) 1-255

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Normally assign

 

 

Release timing for incoming trunk connections.

 

 

 

 

 

data “0”.

 

 

 

0

=

288 msec.

Note

1

=

224 msec.

 

 

 

 

• For ISDN, see Table

 

 

2

=

288 msec.

 

3

=

352 msec.

 

 

 

 

 

4-25(Example of

 

 

4

=

416 msec.

 

5

=

480 msec.

 

 

 

 

 

Route Class

32

ICRL

6

=

544 msec.

 

7

=

608 msec.

 

 

 

 

 

Settings).

 

 

 

8

=

672 msec.

 

9

=

736 msec.

 

 

 

 

 

 

 

 

 

10 =

800 msec.

 

11

=

864 msec.

 

 

 

 

 

 

 

 

 

12 =

928 msec.

 

13

=

992 msec.

 

 

 

 

Note: 160

msec. in

 

 

14 =

1056 msec.

 

15

=

1120 msec.

 

 

 

 

 

case

of Loop

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dialing Trunk.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Trunk Hold Timing.

 

 

 

 

 

 

 

 

 

 

 

 

 

0

=

10 sec.

 

1

=

2 sec.

 

 

 

 

 

 

 

 

 

2

=

4 sec.

 

3

=

6 sec.

 

 

 

 

 

 

 

 

 

4

=

8 sec.

 

5

=

10 sec.

 

 

 

 

Normally assign data

33

HD

6

=

12 sec.

 

7

=

14 sec.

 

 

 

 

 

 

 

 

 

“0”.

 

 

 

 

8

=

16 sec.

 

9

=

18 sec.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10 =

20 sec.

 

11

=

22 sec.

 

 

 

 

 

 

 

 

 

12 =

24 sec.

 

13

=

26 sec.

 

 

 

 

 

 

 

 

 

14 =

28 sec.

 

15

=

30 sec.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ground Timer

 

 

 

 

 

 

 

 

Normally assign

 

 

Outgoing inhibit timing after trunk release.

 

 

 

 

 

data “0.”

 

 

 

0

=

3072 msec.

 

1

=

512 msec.

 

 

 

 

• For ISDN, see Table

 

 

2

=

1024 msec.

 

3

=

1536 msec.

 

 

 

 

 

4-25(Example of

34

GUARD

4

=

2048 msec.

 

5

=

2560 msec.

 

 

 

 

 

Route Class

6

=

3072 msec.

 

7

=

3584 msec.

 

 

 

 

 

Settings).

 

 

 

 

 

 

 

 

 

 

 

 

8

=

4096 msec.

 

9

=

4608 msec.

 

 

 

 

 

 

 

 

 

10 =

5120 msec.

 

11

=

5632 msec.

 

 

 

 

 

 

 

 

 

12 =

6144 msec.

 

13

=

6656 msec.

 

 

 

 

 

 

 

 

 

14 =

7168 msec.

 

15

=

7680 msec.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Width of a Wink Signal

 

 

 

 

 

 

 

 

 

 

 

 

 

0

=

160 msec.

 

1

=

64 msec.

 

 

 

 

 

 

 

 

 

2

=

96 msec.

 

3

=

128 msec.

 

 

 

 

 

 

 

 

 

4

=

160 msec.

 

5

=

192 msec.

 

 

 

 

Normally assign data

35

WINK

6

=

224 msec.

 

7

=

265 msec.

 

 

 

 

 

 

 

 

 

“0.”

 

 

 

 

8

=

288 msec.

 

9

=

320 msec.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10 =

352 msec.

 

11

=

384 msec.

 

 

 

 

 

 

 

 

 

12 =

416 msec.

 

13

=

448 msec.

 

 

 

 

 

 

 

 

 

14 =

480 msec.

 

15

=

512 msec.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

36

VAD

 

 

 

 

 

 

 

0

0

0

0

Always assign data “0.”

 

 

 

 

 

 

 

 

 

 

 

 

 

 

37

CLD

 

 

 

 

 

 

 

0

0

0

0

Always assign data “0.”

 

 

 

 

 

 

 

 

 

 

 

 

Forced Account/Forced Authorization Code

 

 

 

 

 

 

 

38

FA

0

=

Check is not required

 

 

 

 

 

 

 

 

 

 

 

 

1

=

Check is required (For Remote Access to System)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

39

BC

C.O Line Idle Balance Condition.

 

 

 

 

 

 

For Australia only

0

=

Not balanced

 

 

1

= Balanced

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 