NEC NDA-24298 manual Aekd Assignment of External Key Data

Models: NDA-24298

1 1020
Download 1020 pages 51.64 Kb
Page 806
Image 806

AEKD : Assignment of External Key Data

AEKD: Assignment of External Key Data

1.General

This command assigns the External Key related data, which allows a maintenance person to change the system over to the Day/Night mode by means of ON/OFF on the PFT circuit card.

2.Precautions

1.When the “PFT control by the external key” is required, the following data assignments are needed:

(a)AUNT command, TYPE = 2 (PFT)

(b)AEKD command

(c)ANCD command

(d)ACSI command, CSI = 4 (Direct-in Termination (Night Mode))

2.A maximum of eight (0-7) external keys can be assigned, corresponding to each PFT circuit card. The external key can control two PFT circuit cards per MG (16 circuits).

3.Data Entry Instructions

 

 

1

= –

 

CP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

= Day/Night Change

 

 

 

 

 

 

3

= –

 

 

 

 

 

 

 

 

4

= –

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MODULE

 

CIRCUIT

EXTERNAL

 

CHANGE

 

 

 

KEY

 

CONTROL

GROUP

 

CARD NO.

 

 

NUMBER

 

PATTERN

(MG)

 

(NCU PKG)

 

 

(CTN)

 

(CP)

0-7

 

 

0/1

 

 

 

0-7

 

1-4

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

3

 

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

 

 

5

 

 

 

 

 

 

 

 

 

6

 

 

 

 

 

 

 

 

 

 

 

 

 

TN

One external key can manage 8 tenants at the maximum

TN

NUMBER OF INPUT TN or RT/TK (CNT)

1st

2nd

3rd

4th

5th

6th

7th

8th

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CHAPTER 4

NDA-24298

Page 772

Issue 1

Page 806