NEC NDA-24298 If the value exceeds the assigned limit, Polling is not activated. In case 00Hex is

Models: NDA-24298

1 1020
Download 1020 pages 51.64 Kb
Page 214
Image 214

ASYDL : Assignment of System Data into Local DM (LDM)

 

SYSTEM

 

 

BIT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SYSTEM

DATA

CORRESPONDING

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DATA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DATA

(DATA)

 

DATA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INDEX

 

 

 

 

 

 

 

 

 

 

SYSTEM DATA CONTENTS

 

 

TYPE

00 - FF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(SYS)

(INDEX)

(Hex)

DATA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

512 - 1535

 

BIT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0/1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Designate the Polling cycle within the Self Node (for IPX-

 

 

 

 

 

 

 

 

UMG system only) by the number of calls intended for Poll-

 

 

 

 

 

 

 

 

ing of the system. Assign this data to default value “0” or “8”

 

 

 

 

 

 

 

 

in case the number of calls is within 675,000 calls per a day.

 

 

 

 

 

 

 

 

Actual setting is measured declining 30% of calls in the fol-

 

 

 

 

 

 

 

 

lowing values on the list:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

584

 

 

 

b0 ~ b7

 

 

Call/day

System Data

 

 

 

Call/day

System Data

 

 

 

 

 

 

~5,400,000

 

 

 

1

 

 

 

 

 

 

~600,000

9

 

 

 

 

 

 

 

 

 

~2,700,000

 

 

 

2

 

 

 

 

 

 

~540,000

10

 

 

 

 

 

 

 

 

 

~1,800,000

 

 

 

3

 

 

 

 

 

 

~490,000

11

 

 

 

 

 

 

 

 

 

~1,350,000

 

 

 

4

 

 

 

 

 

 

~450,000

12

 

 

 

 

 

 

 

 

 

~1,080,000

 

 

 

5

 

 

 

 

 

 

~400,000

13

 

 

 

 

 

 

 

 

 

~900,000

 

 

 

6

 

 

 

 

 

 

~385,000

14

 

 

 

 

 

 

 

 

 

~770,000

 

 

 

7

 

 

 

 

 

 

~360,000

15

 

 

 

 

 

 

 

 

 

~675,000

 

 

 

8

 

 

 

 

 

 

~337,000

16

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Designate the Polling cycle between the Nodes (for Center

 

 

 

 

 

 

 

 

Node only). When a LN among multiple LNs is set as the

 

 

 

 

 

 

 

 

Center Node of CCIS Centralized Billing, Polling cycle is to

 

 

 

 

 

 

 

 

be changed to prevent from Buffer Overflow in LNs. Usual-

 

 

 

 

 

 

 

 

ly assign the default value “0 (2 seconds cycle)”.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Polling Cycle

System Data

 

 

Polling Cycle

System Data

 

 

585

 

 

 

b0

~ b7

 

 

0.25s

 

 

 

 

1

 

 

 

 

 

 

 

2.25s

9

 

 

 

 

 

 

 

0.50s

 

 

 

 

2

 

 

 

 

 

 

 

2.50s

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

0.75s

 

 

 

 

3

 

 

 

 

 

 

 

2.75s

11

 

 

 

 

 

 

 

 

 

1.00s

 

 

 

 

4

 

 

 

 

 

 

 

3.00s

12

 

 

 

 

 

 

 

 

 

 

1.25s

 

 

 

 

5

 

 

 

 

 

 

 

3.25s

13

 

 

 

 

 

 

 

 

 

 

1.50s

 

 

 

 

6

 

 

 

 

 

 

 

3.50s

14

 

 

 

 

 

 

 

 

 

 

1.75s

 

 

 

 

7

 

 

 

 

 

 

 

3.75s

15

 

 

 

 

 

 

 

 

 

 

2.00s

 

 

 

 

8

 

 

 

 

 

 

 

4.00s

16

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Set the upper limit of polling buffer rate (01%-99%)

 

 

 

 

 

 

 

 

at Centralized Billing Node.

 

 

 

 

 

 

 

 

 

 

 

b7

b6

b5

b4

b3

 

b2

 

b1

b0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Unit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Tens

 

 

 

586

 

 

 

b0

~ b7

Example:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b7

b6

b5

b4

b3

 

b2

 

b1

b0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

0

 

0

 

0

0

 

0

 

0

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note:

 

 

 

 

 

8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

If the value exceeds the assigned limit,

 

 

 

 

 

 

 

 

 

 

 

 

 

polling is not activated. In case 00Hex is

 

 

 

 

 

 

 

 

 

 

 

 

 

assigned to b0 ~ b7, the data is to be

 

 

 

 

 

 

 

 

 

 

 

 

 

assigned to the standard rate 50%.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

587-607

 

 

 

 

 

 

Not used

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CHAPTER 4

 

 

 

NDA-24298

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Page 180

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Issue 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Page 214
Image 214
NEC NDA-24298 manual If the value exceeds the assigned limit, Polling is not activated. In case 00Hex is