APAD : Assignment of PAD Data

APAD: Assignment of PAD Data

1.General

This command assigns PAD control data for tandem connections, and trunk-to-station connections.

2.Precautions

When KIND = 2 (station) is designated, assign the dummy data to the parameter OGPAD.

3. Data Entry Instructions

KIND

The kinds of connections entered in this parameter are as follows: 1 = Tandem Connection

2 = Station

3 = Outgoing (Not used)

4 = Incoming (Not used)

DC

The assignment of this parameter is required only when KIND = 3 (Outgoing) is designated.

This data should be assigned by the AMND command.

ICPAD/OGPAD

0 = No APAD Setting

1-14 = Note1

15 = PAD OFF (0dB)

Note 1: Switch setting varies depending on the trunk circuit card. Refer to “Circuit Card Manual.”

KIND

INCOMING

OUTGOING

 

 

INCOM-

OUTGO-

OF

ROUTE

 

 

DIGIT CODE

ING

ING

ROUTE

 

 

SFC

PAD

CONNEC

 

NUMBER

(DC)

PAD

NUMBER

 

0-15

DATA

-TION

 

(OGRT)

 

MAXIMUM 24 DIGITS

DATA

 

(ICRT)

 

 

 

(ICPAD)

(KIND)

 

 

 

 

 

 

(OGPAD)

1-4

 

 

 

 

 

 

 

1-15

1-15

1

9

0

1

1

0

 

 

 

 

2

 

 

 

1

1

4

 

81

 

SFC

This parameter is not required for the parameter KIND = 1 (Tandem Connec- tion).

ICPAD

ICPAD is not required when assigning KIND as 3 (Outgoing).

OGPAD

The parameter OGPAD is not required when assigning KIND as 4 (Incoming).

NDA-24298CHAPTER 4